To remove the cable:

1.  Turn the forward/off/reverse switch to the off position 

O

 and remove the battery pack.    

2. Pull the cable out through the nose of the drum until 

the anchor cable shows. 

3. Remove the cable from the anchor cable by insert-

ing the pin key into the coupling hole and pulling the 

cable away.

         

       

 

4. To clean or maintain cable, follow the cleaning in-

structions under "Maintenance".                              

To install the cable:

1.  Turn the forward/off/reverse switch to the off position 

O

 and remove the battery pack.

2.  Install the cable to the anchor cable by snapping the 

attachment coupler into the cable coupler.

3. Feed the cable into the drum.

4. Remove the protective tip cover from new cables 

before use.

Cable Attachment Installation

To install the attachment:

Snap the attachment coupler into the cable coupler.  

Test the cable before inserting into the drain to make 

sure the attachment does not fall off during use.

To remove the attachment:

Insert the pin key into the coupling hole and pull attach-

ment off of cable.

Transportation and Set Up

WARNING

Do not transport this tool when the 

drum and backpack are connected. 

Tipping may occur.
To transport the tool:

1. Remove drum from the backpack area. 

 

2. Place the foot pedal in its storage and  

     tie the pedal cord using the cord wrap.

3. Place the backpack over back and 

buckle the chest straps together.

4. Lift the drum to the drain area, as 

shown.

To set up the tool:

1. Once at the drain, area, remove  

   backpack and place it no further  

   than 610mm from the drain. 

  

 

 

2.  Remove the foot pedal and cord from 

the backpack and place to the side, ensuring the cord 

will not tangle with the tool cable.

3. Place the drum onto the powered base by using 

the drum alignment guides. Press drum down onto 

powered base while latching to ensure a complete 

connection.

OPERATION

WARNING

Always remove battery pack before 

changing or removing accessories. 

for this tool. Others may be hazardous.
To reduce the risk of short circuit, when setting tool 

or battery down, do not allow battery to contact 

To reduce the risk of injury, wear safety goggles 

or glasses with side shields. Always wear leather 

gloves.

Using Forward/Off/Reverse Switch

1. For 

forward

 (clockwise) rotation, turn the forward/

off/reverse switch to the arrow pointing towards the 

nose of the drum . Check the direction of rotation 

before use.

2. For

 reverse 

(counterclockwise) rotation, turn the 

forward/off/reverse switch to the arrow pointing away 

from the nose of the drum

 

. Check the direction of 

rotation before use.

3. To 

lock 

the switch, turn the forward/off/reverse switch 

to the centre position 

O

. The foot pedal will not work 

while the forward/off/reverse switch is in the centre 

locked position. Always lock the switch or remove 

the battery pack before performing maintenance, 

changing accessories, storing the tool and any time 

the tool is not in use.

Starting and Stopping Speed

1. To 

start

 the tool, push the forward/off/reverse switch 

to either direction and step or kneel on the foot pedal.

2. To 

stop

 the tool, release pressure on the pedal.

Inserting Cable Into Drain

1.  Transport and set the tool up according to the instruc-

tions under "Transportation and Set Up".

2. Grasp the cable close to the tool and feed at least  

610mm into the drain. 

WARNING!

 Wear leather gloves.

3. Turn the forward/off/reverse switch to the forward 

position 

 

and engage the foot pedal to begin rotating 

the cable.

4. Continue feeding cable 

into the drain until the 

obstruction is reached. 

NOTE:

 If more cable is 

needed to reach the clog, a 

second drum may be con-

nected. To do this, turn the 

forward/off/reverse switch to 

the off position 

O

. Remove 

the drum from the powered 

base and place to the side. 

Insert a new drum onto the 

powered base. Disconnect 

the anchor cable from the 

original drum and and con-

nect it to the anchor cable in the second cable according 

to instructions under "Cable Attachment Installation".

5.  When the clog is reached,  move the cable in a back 

and forth motion until the obstruction is cleared. If 

the tool binds, release pressure from the foot pedal 

immediately. Repeat until the drain is clear.

WARNING! 

Greater distance can 

cause twisting, kinking, breaking or 

whipping of the cable.

Summary of Contents for M18 FFSDC16

Page 1: ...Cat No M18 FFSDC16 M18 FUEL SWITCH PACK SECTIONAL DRUM SYSTEM OPERATOR S MANUAL To reduce the risk of injury user must read and understand operator s manual WARNING...

Page 2: ...and balance at all times This enables better control of the power tool in unexpected situations Dress properly Do not wear loose clothing or jewelry Keep your hair and clothing away from moving parts...

Page 3: ...k or tool outside the temperature Charging im SERVICE person using only identical replacement parts This will ensure that the safety of the power tool is maintained Never service damaged battery packs...

Page 4: ...able tip may be sharp Remove the cable for cleaning after each use Differ ent size and types of cables are available for different applications FUNCTIONAL DESCRIPTION 1 2 1 Handle 2 Inner drum 3 Cable...

Page 5: ...o not allow battery to contact To reduce the risk of injury wear safety goggles or glasses with side shields Always wear leather gloves Using Forward Off Reverse Switch 1 For forward clockwise rotatio...

Page 6: ...nment or binding of moving parts breakage of parts or any other condition that may affect the tool operation Return the tool battery pack and charger to a MILWAUKEE service facility for repair After s...

Page 7: ......

Page 8: ...lly Made in China for Milwaukee Tool Australia Milwaukee Tool New Zealand Printed in China WARRANTY AUSTRALIA and NEW ZEALAND SERVICE AUSTRALIA and NEW ZEALAND MILWAUKEE prides itself in producing a p...

Reviews: