ASSEMBLY

Inserting/Removing the Battery

To 

remove 

the battery, push in the release buttons 

and pull the battery pack away from the tool.
To 

insert

 the battery, slide the pack into the body 

of the tool. Make sure it latches securely into place.

 

WARNING 

Always remove battery 

pack before changing or removing acces-
sories. Only use accessories specifically 
recommended for this tool. Others may be 
hazardous.

WARNING 

To reduce the risk of in-

jury, always remove the battery pack before 
removing the dust box. Do not use tool with-
out dust box and HEPA fi lter in place. 

CAUTION 

Keep  fi lter clean. Effi ciency  of 

the HAMMERVAC™ is largely dependent on 
the fi lter. A dirty fi lter will reduce the air fl ow 
and overall effi ciency of the system. Do not 
clean with water or compressed air. Remove 
from dust box and tap clean.

Attaching the HAMMERVAC™ to a Rotary 
Hammer/Hammer Drill

The HAMMERVAC™ is provided with three clamp-
ing collar assemblies and one side handle grip. 
Choose the correct clamping collar assembly for 
the tool being used (see 

Specifi cations

). The side 

handle grip should be unscrewed from one as-
sembly to be used on another.
1. Turn OFF, remove the battery pack from the 

HAMMERVAC™, and disconnect power from 
the tool.

2. Remove the tool side handle. 
3. Partially screw side handle grip onto clamping 

collar assembly

4. Slide the HAMMER-

VAC™ side handle 
clamping collar as-
s e m b l y   o v e r   t h e 
chuck and onto the 
neck of the tool. The 
clamp lever must be 
facing up (3).

5. Attach the side han-

dle clamping collar 
assembly onto the 
HAMMERVAC™, fi rst 
the upper jaw, then 
lower jaw.

6. Press down the clamp lever (3) to secure the 

clamping collar assembly to the HAMMER-
VAC™. 

7. Rotate the HAMMERVAC™ and side handle 

grip to the desired position, and tighten securely. 

Adjusting the Side Handle Position

1.  Loosen the side handle clamping collar assembly 

by unscrewing the side handle grip until the side 
handle clamping collar assembly rotates freely. 

2.  Rotate the side handle grip to the desired posi-

tion.  

3.  Tighten the side handle grip securely.

Installing/Removing the Bit

Slide the bit through the nozzle and then install 
into the tool according to the tool manufacturer's 
instructions. For best results, use a bit 6" in length 
or shorter.

Fitting the HAMMERVAC™ to the Tool and Bit

For proper suction and depth control, position the 
nozzle assembly so the bit is fl ush with the for-
ward face of the nozzle:
1. Press and hold the tool and 

bit adjustment button. 

2. Push in the nozzle assem-

bly until the bit is fl ush  with 
the front face of the nozzle.

3. Release the tool and bit ad-

justment button.

NOTE: 

Fully extend the HAM-

MERVAC™ before storing to 
preserve spring life. 

Setting the Drilling Depth

1. Fit the HAMMERVAC™ to the Tool and Bit.
2. Press and hold the depth gauge button and 

slide the depth gauge to the desired depth. The 
drilling depth is the last visible measurement 
shown when viewed from the top of the tool. 

1

2

2

1

3

Drill Depth

To ensure the HAMMERVAC™ is properly set 
to the tool, bit, and desired depth, always drill 
a test hole.

Installing/Removing the 
Dust Box and HEPA Filter

To

 remove

 the dust box:

1.  Turn OFF the tool.
2. Remove the battery pack.  
3. Press the dust box latch down.
4. Pull the dust box away from 

the HAMMERVAC™.

5. Empty dust from the dust box. 
6. If necessary, pull the HEPA 

fi lter away from the dust box 
and tap clean. Do not clean 
with water or compressed 
air. After about 1500 holes or 
loss of suction, discard and 
replace HEPA fi lter (Cat. No. 
49-90-2306).

To 

install 

the dust box:

1. Slide the dust box into the body of the HAM-

MERVAC™. 

2. The dust box latch should snap into place.

NOTE: 

 Do not operate the HAMMERVAC™ with-

out the dust box and HEPA fi lter in place. Dust box 
cannot be installed without HEPA fi lter.

SYMBOLOGY

SPECIFICATIONS

Volts

Underwriters Laboratories, Inc.
United States and Canada

Direct Current

Cat. No. Volts

 

DC

Max. Bit 

Diameter

For use with Hammer Collar Sizes 

Diameter / Circumference

2306-20

12

5/8"

S = Ø 43 mm - 46 mm (1.7"-1.8") / 135 mm - 144.5 mm (5.3"-5.7")
M = Ø 48 mm – 55 mm (1.9"-2.2") / 151 mm - 173 mm (6"-6.9")
L = Ø 56 mm - 59 mm (2.2"-2.3") / 176 mm - 185 mm (6.9"-7.2")

Installing/Removing Nozzle Assembly

To install the nozzle assembly 
supplied with the tool, or ac-
cessory nozzles:
1.  With the nozzle assembly 

pointing straight up, line 
up the lugs of the nozzle 
assembly with the lugs on 
the front of the HAMMER-
VAC™. The unlock symbol 

on the nozzle assembly 

will line up with the mark on 
the top of the HAMMER-
VAC™.

2.  Turn the nozzle assembly 

left or right to lock into place. 
The lock symbol 

on the 

nozzle assembly will line up 
with the mark on the top of 
the HAMMERVAC™.

3. To remove, reverse the 

procedure.

Installing/Removing Nozzle

Replace the nozzle:
• After drilling about 1500 holes,
• When the  bit brush shows signs 

of wear,

• When suction is reduced, 
• When dust escapes through the 

bit brush during use 

To replace the nozzle (Cat. No. 
49-90-2300), press in the release 
button and pull out from the lower 
nozzle assembly. Slide the new 
nozzle into the lower nozzle as-
sembly until it snaps into place. 

Correct

Incorrect

Incorrect

Summary of Contents for M12 HAMMERVAC 2306-20

Page 1: ...VAC OPERATOR S MANUAL MANUEL de L UTILISATEUR MANUAL del OPERADOR TO REDUCE THE RISK OF INJURY USER MUST READ AND UNDERSTAND OPERATOR S MANUAL AFIN DE R DUIRE LE RISQUE DE BLESSURES L UTILISATEUR DOIT...

Page 2: ...ou are tired distracted or under the influence of drugs alcohol or medication causing diminished control The operation of a dust extractor can result in foreign objects being blown into eyes which can...

Page 3: ...ld the tool and bit adjustment button 2 Push in the nozzle assem bly until the bit is flush with the front face of the nozzle 3 Release the tool and bit ad justment button NOTE Fully extend the HAM ME...

Page 4: ...kmanship for a period of five 5 years after the date of purchase unless otherwise noted Return of the power tool to a MILWAUKEE factory Service Center location or MILWAUKEE Authorized Service Station...

Page 5: ...BASE VEUILLEZ LIRE TOUTES LES INSTRUCTIONS AVANT D UTILISER LE D POUSSI REUR POUR UTILISATION DOMESTIQUE OU COMMERCIALE AVANT D UTILISER LE D POUSSI REUR VEUILLEZ LIRE LE MANUEL DE L UTILISATEUR LES M...

Page 6: ...loquet de la boite poussi re devrait se remettre en place NOTE Ne pas faire fonctionner le HAMMER VAC sans que la boite poussi re ni le filtre HEPA ne soit en place La boite poussi re ne doit pas tre...

Page 7: ...ter la position de la poign e lat rale 1 Desserrez le collier de serrage de la poign e lat rale en d vissant la poign e lat rale jusqu ce que le collier tourne librement 2 Tournez la poign e lat rale...

Page 8: ...les Miguel Hidalgo Distrito Federal Mexico Ph 52 55 4160 3547 IMPORT ET COMMERCIALIS PAR TECHTRONIC INDUSTRIES MEXICO S A DE C V Av Presidente Mazarik 29 Piso 7 11570 Chapultepec Morales Miguel Hidalg...

Page 9: ...qu micos debe hacer lo siguiente trabajar en un rea bien ven tilada y usar el equipo de seguridad adecuado MANTENIMIENTO USO Y CUIDADO DE LAS HERRAMIENTAS CON BATER A LEA Y CONSERVE TODAS LAS INSTRUC...

Page 10: ...or de polvo depende mucho del filtro Un filtro sucio reduce la circulaci n del aire y la eficacia del sistema de filtrado No lo limpie con agua ni aire comprimido Elimine el polvo del recipiente y sac...

Page 11: ...broca Deslice la broca por la escobilla de la broca y luego inst lela en la herramienta seg n las instrucciones del fabricante de la herramienta Para obtener mejores resultados use una broca de hasta...

Page 12: ...Federal Mexico Tel 52 55 4160 3547 IMPORTADO Y COMERCIALIZADO POR TECHTRONIC INDUSTRIES MEXICO S A DE C V Av Presidente Mazarik 29 Piso 7 11570 Chapultepec Morales Miguel Hidalgo Distrito Federal Mexi...

Page 13: ...ATENCI N A CLIENTES Av Presidente Mazarik 29 Piso 7 11570 Chapultepec Morales Miguel Hidalgo Distrito Federal Mexico Telefono 52 55 4160 3547 e mail servicio ttigroupna com Adicionalmente tenemos una...

Reviews: