MIL'S ARICA 100 User Manuals Download Page 8

ARICA

 

11

16

26

40

61

80

100

 

 

519924.03

 

 

6

 

 

 

 

GB

 

 

1.

 

INTRODUCTION

 

7

 

 

S

PECIFICATION

 

PLATE

 

7

 

1.1.

 

U

SE

 

7

 

1.2.

 

C

ONTRAINDICATIONS

 

7

 

1.3.

 

C

HARACTERISTICS

 

7

 

1.4.

2.

 

INSTALLATION

 

8

 

 

H

ANDLING

 

AND

 

STORAGE

 

8

 

2.1.

 

C

HOICE

 

OF

 

LOCATION

 

AND

 

TEMPERATURE

 

8

 

2.2.

 

P

UMP

 

INSTALLATION

 

8

 

2.3.

 

U

SER

 

SYSTEM

 

8

 

2.4.

 

I

NTAKE

 

AND

 

OUTLET

 

CONNECTIONS

 

8

 

2.5.

 

W

IRING

 

8

 

2.6.

3.

 

COMMISSIONING

 

9

 

 

O

PERATION

 

9

 

3.1.

4.

 

MAINTENANCE

 

9

 

 

G

ENERAL

 

WARNINGS

 

9

 

4.1.

 

M

AINTENANCE

 

TABLE

 

9

 

4.2.

 

S

PARE

 

PARTS

 

10

 

4.3.

5.

 

DISMANTLING

 

10

 

6.

 

TROUBLESHOOTING

 

10

 

7.

 

SAFETY

 

SHEET

 

10

 

8.

 

SPARE

 

PARE

 

LIST

 

10

 

 

 
 
 
 
 
 
 

MEANING

 

OF

 

THE

 

PICTOGRAMS

 

USED

 

IN

 

THIS

 

MANUAL

 

 
 
 
 

Pictograms

 

have

 

been

 

inserted

 

into

 

the

 

manual

 

to

 

make

 

it

 

clearer

 

and

 

to

 

indicate

 

particular

 

points

 

that

 

should

 

be

 

observed

 

or

 

taken

 

into

 

account,

 

as

 

follows:

 

 

Reading

 

symbol

:

 

This

 

pictogram

 

indicates

 

particular

 

points

 

and

 

information

 

given.

 

 

Attention

 

symbol

:

 

This

 

pictogram

 

indicates

 

that

 

failure

 

to

 

observe

 

this

 

symbol

 

may

 

result

 

in

 

personal

 

injury

 

and

 

possibly

 

damage

 

to

 

the

 

machine.

 

A

 

specific

 

reminder

 

is

 

made

 

of

 

the

 

regulations

 

and/or

 

proper

 

application

 

of

 

certain

 

precautions.

 

 

Danger

 

symbol

:

 

This

 

pictogram

 

represents

 

the

 

DIN

 

symbol

 

4844

 

(hazard

 

warning)

 

that

 

warns

 

of

 

a

 

hazard

 

that

 

could

 

cause

 

death

 

or

 

personal

 

injury

 

with

 

damage

 

to

 

the

 

machine.

 

All

 

personnel

 

working

 

on

 

this

 

machine

 

must

 

comply

 

with

 

this

 

symbol.

 

Work

 

safety

 

regulations

 

must

 

be

 

observed.

 

 

Environment

 

protection

 

symbol

:

 

This

 

pictogram

 

calls

 

to

 

mind

 

the

 

requirement,

 

during

 

maintenance

 

operations,

 

to

 

sort

 

the

 

waste,

 

store

 

it

 

in

 

a

 

safe

 

place

 

and

 

dispose

 

of

 

it

 

in

 

an

 

environmentally

responsible

 

manner.

 

 

  

Dustbin

 

on

 

wheels

 

barred

 

of

 

a

 

cross

 

symbol:

 

This

 

symbol

 

indicates

 

that

 

the

 

equipment

 

should

 

not

 

be

    

thrown

 

with

 

domestic

 

waste

 

and

 

is

 

subject

 

to

 

selective

 

collection.

 

 

 

Summary of Contents for ARICA 100

Page 1: ...ttp www mils eu e mail sales mils fr 519924 03 03 2016 POMPES A VIDE SECHES et SURPRESSEURS OIL FREE ROTARY VANE VACUUM PUMPS and BLOWERS BOMBAS DE VAC O SECAS y COMPRESORES BOMBAS DE V CUO SECAS e SO...

Page 2: ...from MIL S company Failure to respect this requirement may lead to prosecution Este documento no puede transmitirse o reproducirse sin la autorizaci n de la empresa MIL S No respetar esta cl usula pu...

Page 3: ...rammes sont Symbole lecture Ce pictogramme indique les points particuliers et des renseignements donn s Symbole attention Ce pictogramme indique que le non respect de ce symbole peut entra ner des ble...

Page 4: ...our pomper des gaz explosifs inflammables corrosifs ou qui forment des particules L utilisation de la pompe dans ces atmosph res et avec ces types de gaz peut provoquer des l sions des explosions des...

Page 5: ...re de vibrations la pompe Assurer le changement d air dans la pi ce ou l int rieur de la machine dans laquelle se trouve la pompe et viter que l air provenant de l vacuation ou des ventilateurs de ref...

Page 6: ...ion utilisatrice pendant 30 minutes environ Cette op ration permet de se d barrasser de la pr sence ventuelle de condensation dans la chambre d aspiration ce qui vite l oxydation des parties internes...

Page 7: ...ris es Fournir l alimentation lectrique V rifier les causes qui l ont d clench et activer l interrupteur Amener la temp rature ambiante dans l intervalle admis S adresser au service d assistance S adr...

Page 8: ...ram indicates particular points and information given Attention symbol This pictogram indicates that failure to observe this symbol may result in personal injury and possibly damage to the machine A s...

Page 9: ...the pump to pump explosive flammable or corrosive gases or gas that form particles Using the pump in these atmospheres and with these types of gases can cause injury explosion fire or serious damage...

Page 10: ...nts Whenever the model has not been equipped ensure installation of such equipment so as not to transmit vibration to the pump Ensure there is ventilation in the room or inside the machine housing the...

Page 11: ...minate it Stop The pump must be stopped by cutting off the power supply If the pump is to be powered off let it run with open intake isolated from the user system for about 30 minutes first This will...

Page 12: ...collection and recovery must be done by service providers authorised in accordance with the current regulations 6 TROUBLESHOOTING Problems Possible cause Solution The pump does not run No voltage Ther...

Page 13: ...on S mbolo lectura Este pictograma indica los puntos particulares e informaciones dadas S mbolo cuidado Este pictograma indica que no respetar este s mbolo puede ocasionar heridas y eventualmente da o...

Page 14: ...tica o de alta concentraci n de polvos o sustancias aceitosas suspendidas en el aire ni emplearla para bombear gases explosivos inflamables corrosivos o que formen part culas El uso de las bombas en...

Page 15: ...realizarse como accesorio para que la bomba no transmita vibraciones Asegurarse que exista circulaci n de aire en el local o dentro de la m quina donde se instala la bomba con el fin de evitar que el...

Page 16: ...a alimentaci n el ctrica del motor En caso de apagado recomendamos hacer funcionar la bomba con la aspiraci n abierta y aislada de la instalaci n del usuario durante unos 30 minutos Esta operaci n per...

Page 17: ...Soluciones La bomba no funciona Falta de tensi n Interruptor t rmico activado Temperatura ambiente demasiado baja Bobina motor da ada Aspiraci n de sustancias no permitidas Conectar la alimentaci n e...

Page 18: ...Leitura Este pictograma indica os pontos particulares e as informa es dadas S mbolo Aten o Este pictograma indica que o n o respeito por este S mbolo pode causar ferimentos e eventualmente avarias na...

Page 19: ...flam veis corrosivos ou que formem part culas A utiliza o da bomba nestas atmosferas e com estes tipos de gases pode provocar les es explos es inc ndios ou avarias na bomba N o usar pe as sobressalent...

Page 20: ...caso o modelo n o f r provido com os mesmos efetuar a instala o destes acess rios de modo a n o transmitir vibra es bomba Certificar se do arejamento no local ou dentro da m quina onde estiver colocad...

Page 21: ...pendo a alimenta o el trica do motor No caso de desligamento recomendamos fazer funcionar a bomba com a aspira o aberta e isolada da instala o do usu rio durante aproximadamente 30 minutos Esta opera...

Page 22: ...m vigor 6 RESOLU O DE AVARIAS Inconvenientes Causas Solu o A bomba n o parte Falta de tens o Interruptor t rmico desligado Temperatura ambiente muito baixa Bobinagem do motor danificada Aspira o de su...

Page 23: ...stances explosives OUI NON L appareil contient il des substances radioactives OUI NON Autres OUI NON CMR canc rig ne mutag ne reprotoxique Si pr sence de mati res radioactives ou explosives num rer le...

Page 24: ...device contain explosive substances YES NO Does the device contain radioactive substances YES NO Others YES NO CMR carcinogenic mutagenic reprotoxic If radioactive or explosive materials are present...

Page 25: ...M8x25 Screw M8X25 Tornillo M8x25 Parafuso M8x25 Vite TE M8X25 10 4 Vis M6x20 Screw M6x20 Tornillo M6x20 Parafuso M6x20 Vite TCCE M6X20 11 3 Vis M6x80 Screw M6x80 Tornillo M6x80 Parafuso M6x80 Vite TCC...

Page 26: ...x18 Pasador 5x18 Pino 5x18 Spina cilindrica 5x18 12 1 Vis M8x25 Screw cylindric M8x25 Tornillo M8x25 Parafuso M8x25 Vite TCCE M8x25 13 1 Rondelle 8 Schnorr washer 8 Arandela 8 Anilha 8 Rondella Shnorr...

Page 27: ...x18 Pasador 5x18 Pino 5x18 Spina cilindrica 5x18 12 1 Vis M8x25 Screw cylindric M8x25 Tornillo M8x25 Parafuso M8x25 Vite TCCE M8x25 13 1 Rondelle 8 Schnorr washer 8 Arandela 8 Anilha 8 Rondella Shnorr...

Page 28: ...30 Vite TCCE M6x30 12 1 Vis M8x25 Screw cylindric M8x25 Tornillo M8x25 Parafuso M8x25 Vite TCCE M8x25 13 1 Rondelle 8 Schnorr washer 8 Arandela 8 Anilha 8 Rondella Shnorr 8 14 1 Rondelle Washer Arande...

Page 29: ...waste electrical and electronic equipment WEEE De la directive 2002 95 CE du Parlement europ en et du Conseil du 8 juin 2011 relative la limitation de l utilisation de certaines substances dangereuse...

Page 30: ......

Page 31: ...________ __________________________________________________________________________________________ __________________________________________________________________________________________ _________...

Page 32: ......

Reviews: