Service Connections
PELLERIN MILNOR CORPORATION
Table 2: Table of Piped Inlets
Description of
Connections
Source Requirements
Piping Specifications,
Comments
Compressed
air--hydraulic tilting
and non-tilt models
1/4" NPT, 85 - 110 PSI (5.97 -
7.73 kg.sq. cm.)
Cold water inlet
Hot water inlet
2" NPT 10 - 75 PSI (0.7 -5.27
kgs.sq. cm.)
Steam inlet
1 - 1/4" NPT 30 - 115 PSI (2.10 -
8.08 kgs. sq. cm.)
Compressed air--air
tilting models
3/4" NPT 85 - 110 PSI (5.97 - 7.73
kg.sq. cm.)
Compressed
air--hydraulic tilting
and non-tilting models
1/4" NPT 85 - 110 PSI (5.97 - 7.73
kg.sq. cm.)
Pipe material per plumbing code
2.1.
Piped Outlet Specification
—Piped outlet requirements are as follows (see dimensional
drawings for sizes and locations of connection points):
Table 3: Table of Piped Outlets
Description of
Connections
Destination Requirements or
Description
Piping Specifications
Drain
8" OD (not tilted)
Vent
4" Diameter
Rubber hose, PVC, or other
approved material per plumbing
code
2.2.
Precautions for Electrical Connections
WARNING 3 : Electrocution Hazard
—Contact with high voltage can kill or seriously
injure you.
• All electrical connections must be made by a competent electrician.
1. Connections must be made by a competent electrician.
2. See the fuse and wire sizing information in the schematic manual and on the machine
nameplate.
3. “Stinger leg” if any, must be connected to terminal L3, never to terminals L1 or L2.
4. Only use BUSSMAN FUSETRON FRN (up to 250V), FRS (up to 600V), or similar lag fuses.
The nameplate fuse sizes must not be applied to standard fuses.
5. See nameplate for fuse and wire size. For wire runs more than 50 feet (15.24 meters),
increase by one wire size per each additional 50 feet.
6. Make the power and liquid supply electrical connections within junction box on the rear of
the machine.
7. Verify all motor rotation as shown in FIGURE 1 (See the operating and troubleshooting
manual for more information). If the cylinder turns in the wrong direction, see note below.
Note 1:
Before shipping, all motors are properly phased for correct rotation. It is possible to reverse
the direction of rotation in a three-phase machine by interchanging the incoming power leads.
Therefore, the rotation of a three-phase machine must be observed and corrected when the machine is
first installed. If it is necessary to reverse the rotation, simply swap the incoming power lines to the
50
Summary of Contents for 68036M5K
Page 2: ......
Page 8: ......
Page 9: ...Safety 1 5 ...
Page 43: ...Installation 2 39 ...
Page 56: ......
Page 57: ...Drive 3 53 ...
Page 99: ...Frame and Tilt 4 95 ...
Page 107: ...Hydraulic Assemblies 5 103 ...
Page 116: ......
Page 117: ...Door Assemblies 6 113 ...
Page 133: ...DRYEL Loading 7 129 ...
Page 144: ......
Page 145: ...Water and Steam 8 141 ...
Page 164: ......
Page 165: ...Chemical 9 161 ...
Page 170: ......
Page 171: ...Control and Sensing Assemblies 10 167 ...
Page 177: ...Dimensional 11 173 ...
Page 178: ......
Page 179: ...175 ...
Page 180: ...176 ...
Page 181: ...177 ...
Page 182: ......
Page 183: ...179 ...
Page 184: ...180 ...
Page 185: ...181 ...