![Milnor 60 Series Maintenance Manual Download Page 23](http://html1.mh-extra.com/html/milnor/60-series/60-series_maintenance-manual_1797177023.webp)
Chapter 2. Safety
PELLERIN MILNOR CORPORATION
Figure 3: Incorrect Configurations That Let the Chemical Supply Go In the Machine by Gravity
Schematic Views
Legend
P.
Pump
T.
Chemical tank
D.
Chemical tube. Liquid in the gray areas can go in the machine.
.
2.2.2.
Equipment and Procedures That Can Prevent Damage
2.2.2.1.
Use the Chemical Manifold Supplied.
—There is a manifold on the machine to attach
chemical tubes from a chemical pump system. Figure 3 shows examples. The manifold has a
source of water to flush the chemical supplies with water.
Figure 4: Examples of Manifolds for Chemical Tubes. Your equipment can look different.