Chapter 3. Routine Maintenance
PELLERIN MILNOR CORPORATION
Table 3: Filters, Screens, and Sensitive Components
Remove contamination from these components to prevent damage and unsatisfactory performance.
Mark
1
2
3
4
5
6
Do this each
Component
x
40 to 60 hours
inverter fans, vents, filters
See
. Keep good air flow.
x
600 hours
motors
Keep good air flow.
x
2400 hours
entire machine
Remove excessive dust and dirt.
x
day*
chemical inlet areas
Some chemical supplies that stay on machine
surfaces will cause corrosion damage. See
From Chemical Supplies and Chemical
Systems”
x
day*
self-purging filter (and
regulator) for compressed air
See
automatically.
x
200 hours
filter element for the filter
(and reguator)
Replace the filter if you cannot remove
contamination.
x
2400 hours
strainer in water regulator for
optional supply injector and
pumped chemicals on some
models.
See
x
200 hours
strainer(s) for air inlet
See
x
200 hours
strainer for steam inlet.
(Steam is optional on some
models.)
See
x
200 hours
speed sensor (photoeye)
See
Table 4: Fluid Containers
Examine. Add fluid if necessary and keep components clean to prevent damage.
Mark
1
2
3
4
5
6
Do this each
Component
More Data. See also
“Lubricant Identification and Procedures”
x
200 hours
Disk brake reservoir
See
. Examine the oil level and
quality. Add oil Dot3 (
If the oil is contaminated, it is necessary to
bleed the brake system. Speak to your dealer
or Milnor. This is not routine maintenance.
22
Summary of Contents for 48040H7R
Page 2: ......
Page 4: ......
Page 5: ...English 1 1 ...
Page 6: ......
Page 8: ...Applicable Milnor products by model number 48040F7J 48040F7W 48040F7Z 48040H7R 48040H7W 4 ...
Page 45: ...Español 2 41 ...
Page 46: ......
Page 48: ...Productos aplicables de Milnor por número de modelo 48040H7W 68036H5W 44 ...