Chapter 3. Routine Maintenance
PELLERIN MILNOR CORPORATION
4. Add grease EM (
) with the motor stopped. If the motor with the nameplate in
operates at 60 Hz, the specified grease quantity for each grease fitting is 0.65 fl oz (18.4
mL).
5. If the motor has a grease drain plugs, operate the machine or use manual functions to operate
the motor for two hours. Replace the drain plug.
Table 11: Motor Grease Intervals and Quantities. Use grease EM (
Interval
Quantity
NEMA (IEC)
Frame Size
RPM Less Than
or Equal To
Years
Hours
Fluid
Ounces
mL
900
5.5
11000
1200
4.5
9000
1800
3
6000
Up to 210 (132)
3600
1.5
3000
0.34
9.5
900
4.5
9000
1200
3.5
7000
1800
2.5
5000
>210 to 280 (132
to 180)
3600
1
2000
0.65
18.4
900
3.5
7000
1200
3
6000
1800
2
4000
>280 to 360 (180
to 200)
3600
0.5
1000
0.87
24.6
900
2.5
5000
1200
2
4000
1800
1
2000
>360 to 5000
(200 to 300)
3600
0.5
1000
2.23
63.2
29