Page EN-8
Pointek ULS200 – QUICK START MANUAL
7ML19981XB83
mmmmm
English
Operation
Start Up
With the ULS200 correctly installed (or aimed at a wall 0.25 to 5 m away), apply power and
view the start up sequence. It will light all possible LED values, show product revision number,
product model number, and will enter run mode. Then, the display shows the measurement of
the distance from the transducer face to the material level in the units indicated.
Display / Operation Status
Operation Status - Run Mode
Quick Start
To set a basic high/low application where you can easily adjust the measured distance, use
the method below. The Pointek ULS200 relays are preset as: relay 1 = alarm 1, high alarm at
0.25 m; relay 2 = alarm 2, low alarm at 5.00 m.
To change the setpoints by reference method, set the material or target to the distance as
displayed. Press the ` 1 /
↑
‘or ` 2 /
↓
' key. The display shows the current setpoint function and
value. Press the alarm key a second time so the ULS200 changes the setpoint to the value
currently being measured. After viewing or changing the setpoint, the Pointek ULS200 reverts
to the run mode.
relay 1
1.
Position the unit so that it reads 0.75 m.
2.
Press 1 /
↑
3.
Press 1 /
↑
4.
Once installed, the unit will register a high alaram at 0.75 m from the sensor face. If
Loss of Echo
appears, complete steps 1 to 3 again.
- echoes are valid and within range.
- echoes are lost due to poor conditions or out of range. This may be typical in
applications where there are deep vessels and the material level is normally out of
range. Refer to Troubleshooting.
- extended loss of echo period. Operation has gone into fail-safe. Refer to
Troubleshooting.
function display: high alarm
current setpoint, 0.5 m
output 1
output 2
operation status
reading
units
↑
key
↓
key
program
mode
adjustment
value
units
Summary of Contents for pointek uls200
Page 1: ...Quick Start Manual March 2010 ULS200 pointek...
Page 2: ...IQ300IX fm Page 5 Tuesday October 2 2001 1 43 PM...
Page 20: ...Page EN 18 Pointek ULS200 QUICK START MANUAL 7ML19981XB83 mmmmm English...
Page 38: ...Side DA 18 Pointek ULS200 KVIKSTART MANUAL 7ML19981XB83 mmmmm Dansk...
Page 56: ...Seite DE 18 Pointek ULS200 KURZANLEITUNG 7ML19981XB83 mmmmm Deutsch...
Page 74: ...EL 18 Pointek ULS200 7ML19981XB83 mmmmm...
Page 92: ...P gina ES 18 Pointek ULS200 GU A PARA LA PUESTA EN MARCHA R PIDA 7ML19981XB83 mmmmm Espa ol...
Page 110: ...Page FR 18 Pointek ULS200 MISE EN SERVICE SIMPLIFIEE 7ML19981XB83 mmmmm Fran ais...
Page 128: ...Pagina IT 18 Pointek ULS200 MANUALE PER L AVVIO RAPIDO 7ML19981XB83 mmmmm Italiano...
Page 146: ...Pagina NL 18 Pointek ULS200 QUICK START HANDLEIDING 7ML19981XB83 mmmmm Nederlands...
Page 164: ...P gina PT 18 Pointek ULS200 MANUAL DE ARRANQUE R PIDO 7ML19981XB83 mmmmm Portugu s...
Page 182: ...Sivu SU 18 Pointek ULS200 PIKAK YTT OPAS 7ML19981XB83 mmmmm Suomi...
Page 200: ...Sida SV 18 Pointek ULS200 MANUAL F R SNABBSTART 7ML19981XB83 mmmmm Svenska...