OM-245778 Page 14
5-2.
Air-Cooled Feeder Connections
Ref. 246 218-C
1
Gas Fitting
Connect one end of 10 ft (3 m) gas
hose to rear of unit, gas solenoid fit-
ting. Connect remaining end of
hose to regulator/flowmeter.
.
Shielding gas pressure not to
exceed 100 psi (689 kPa).
2
Weld Cable To Welding Power
Source
Select and prepare weld cable
according to welding power source
manual.
3
Weld Cable Grommet
4
Current Sensing (Reed) Relay
5
Weld Cable Terminal In
Feeder
Route one end of weld cable
through grommet, through reed
relay, and connect to weld cable ter-
minal in feeder. Connect remaining
end of cable to positive (+) weld
output terminal on welding power
source.
Tools Needed:
9/16 in.
3
2
4
5
1
Rear Panel
Connect To Positive (+)
Weld Output Terminal On
Welding Power Source
Connect To 14-Socket
Receptacle On Welding
Power Source
2
5
Top View