OM-287388 Page 16
SECTION 5
−
OPERATION
5-1. Front Panel Controls
1
Optional Voltage/Wire Speed
Meter
Use switch to choose volts or wire
feed speed display.
2
Optional Remote Voltage
Control
Use control to set welding power
source voltage at the wire feeder.
Numbers are for reference only.
3
Wire Speed Control
4
Gas Purge Switch
Press Gas Purge Switch to ener-
gize gas valve to purge air from
gun, or adjust gas regulator.
5
Trigger Hold Switch
Push switch up to weld without
holding gun trigger throughout the
weld cycle.
To start weld cycle, press and re-
lease gun trigger within three se-
conds after an arc has been struck.
To end weld, press and release gun
trigger.
Power switch is on rear panel (see
Water Cooling In (Red)
7
Water Cooling Out (Blue)
8
Welding Torch Connector
Ref. 805 230-A
1
2
3
4
6
5
8
7
ST-24wD