OM-222 166 Page 46
RemCmd: 1023 Off Cable1: LQD DIAG1
OutI1: 0 A Cable2: LQD
OutI2: 0 A ClntFR: 0.75 GPM
IsrcFb: 0 A ClrSts: Flowing
System Diagnostic Screen
RemCmd
−
This is the value of the remote command and the status of the remote contactor.
Remote controls can be used to enable/disable output. They do not affect output
power level.
NOTE
Out I1
−
This is the value of the output current on output 1.
Out I2
−
This is the value of the output current on output 2.
Isrc FB
−
This is the value of the amperage in the current source inverter.
Cable 1
−
This is the cable type hooked up to output number one. Possible labels:
S
AIR
−
for an air-cooled cable
S
LQD
−
for a liquid-cooled cable
S
PLUG
−
for a protective plug
S
OPEN
−
no cable or plug in place
Cable 2
−
This is the cable type hooked up to output number two. Possible labels:
S
AIR
−
for an air-cooled cable
S
LQD
−
for a liquid-cooled cable
S
PLUG
−
for a protective plug
S
OPEN
−
no cable or plug in place
ClntFR
−
This is the coolant flow rate (in GPM) from the cooler on a liquid-cooled system.
ClrSts
−
This is the status of the cooler. Possible labels:
S
Off
S
Flowing
The second diagnostic screen is available by again pressing and holding the Run Status
button and pressing
the Parameters
Hz
V
A
kW
button.
VLnA
−
B: 460V Therm1: 75 DIAG2
VLnB
−
C: 460V Therm2: 75 Therm5: OPEN
VLnC
−
A: 460V Therm3: 75 ClrTmp: 77
VBus: 650V Therm4: OPEN RmtFlw: Off
System Diagnostic Screen