INSTALLATION
4-1. Specifications
Output
Frequency
Rated Output
Required
Reflective
Inductance
Amperes Input at
Rated Load Output
50 or 60 Hz,
Three-Phase
Overall
Dimensions
Weight
Frequency
Single
Output
Dual
Output
Inductance
400 V
460 V
575 V
kVA
kW
Dimensions
5 To 30
kHz
35 kW At
100% Duty
Cycle
350 A
(RMS), 700
V (RMS)
35 kW At
100% Duty
Cycle
700 A
(RMS),
700 V
(RMS)
2.5 To 50
μ
h
60 A
50 A
40 A
39
37
Length: 36-3/4 in
(993 mm)
Width: 21-1/2 in
(546 mm)
Height: 29 in
(737 mm)
227 lb
(103 kg)
*While idling
WARNING
HIGH-FREQUENCY RADIATION can interfere with radio navigation, safety services,
computers, and communications equipment.
•
Have only qualified person familiar with electronic equipment perform this installation.
•
The user is responsible for having a qualified electrician promptly correct any interference problem resulting from the installation.
•
If notified by the FCC about interference, stop using the equipment at once.
•
Have the installation regularly checked and maintained.
•
Keep high-frequency source doors and panels tightly shut.