![Miller ProHeat 35 OM-222 166F Owner'S Manual Download Page 36](http://html1.mh-extra.com/html/miller/proheat-35-om-222-166f/proheat-35-om-222-166f_owners-manual_1796234036.webp)
OM-222 166 Page 30
S
Ramp increases or decreases the temperature in the part at a controlled rate in degrees per hour. A
maximum temperature of 1450
°
F (788
°
C) and a maximum rate of 9999
°
F/hr (5555
°
C/hr) can be
programmed.
S
Soak will hold the temperature for a programmed time. A maximum hold (soak) time of 99:59
(hours:minutes) can be programmed.
S
End is programmed to indicate the completion of the cycle and termination of output power.
Step Function
When type is set to Step, the following screen appears on the display:
Mode.......: Custom Program
Segment....: 1
Type.......:>Step
Temperature: 600
Custom Program Screen
Use the Cursor
button to move the cursor to the Temperature position and the initial temperature can be
adjusted using the Increase
or Decrease
button.
Pressing the Cursor
button again automatically advances the program to the next segment number.
Ramp Function
When type is set to Ramp, the following screen appears on the display:
Mode.......: Custom Program
Segment....: 1
Type.......: Ramp
Temperature: 600 Ramp Rate: 600
_
/Hr
Custom Program Screen
Use the Cursor
button to move the cursor to the Temperature or Ramp Rate position and use the Increase
or Decrease
button to set the desired value.
When the cursor is in the Ramp Rate position, pressing the Cursor
button again automatically advances
the program to the next segment number.