![Miller ProHeat 35 OM-222 166F Owner'S Manual Download Page 38](http://html1.mh-extra.com/html/miller/proheat-35-om-222-166f/proheat-35-om-222-166f_owners-manual_1796234038.webp)
OM-222 166 Page 32
Typical 5-Segment Custom Program
Mode.......: Custom Program
Segment....: 1
Type.......:>Step
Temperature: 600
Custom Program Screen
Temperature increases to 600 degrees at full-programmed power.
Mode.......: Custom Program
Segment....: 2
Type.......: Ramp
Temperature:>1250 Ramp Rate: 600
_
/Hr
Custom Program Screen
Controlled heating to 1250 degrees F at a ramp of 600 degrees per hour.
Mode.......: Custom Program
Segment....: 3
Type.......: Soak
Soak Time..:>01:00:00
Custom Program Screen
Soak at 1250 degrees F for a period of 1:00.
Mode.......: Custom Program
Segment....: 4
Type.......:>Ramp
Temperature: 600 Ramp Rate: 600
_
/Hr
Custom Program Screen
Controlled cooling to 600 degrees F at a rate of 600 degrees per hour.
Mode.......: Custom Program
Segment....: 5
Type.......: End
Control TC.: 1
Custom Program Screen
End segment ends the heat treat cycle. Controller is programmed to control the process using four thermocouples.