OM-269631 Page 23
5-7. Connecting To Weld Output Terminals
!
Turn off power before connecting
to weld output terminals.
!
Do not use worn, damaged, under-
sized, or repaired cables.
1
Positive (+) Weld Output Terminal
2
Negative (
−
) Weld Output Terminal
Connect positive weld cable to Positive
(+) weld terminal and negative (
−
) cable
to Negative weld terminal.
.
For welding output terminal connec-
tions see Sections 5-2 thru 5-3 for typ-
ical connection processes.
Ref. 250 702-B
1
2
5-8. Connecting Weld Output Cables
803 778-B
!
Turn off power before connecting to
weld output terminals.
!
Failure to properly connect weld
cables may cause excessive heat
and start a fire, or damage your
machine.
1
Weld Output Terminal
2
Supplied Weld Output Terminal Nut
3
Weld Cable Terminal
4
Copper Bar
Remove supplied nut from weld output
terminal. Slide weld cable terminal onto
weld output terminal and secure with nut so
that weld cable terminal is tight against
copper bar.
Do not place anything
between weld cable terminal and copper
bar. Make sure that the surfaces of the
weld cable terminal and copper bar are
clean.
Tools Needed:
3/4 in. (19 mm)
4
2
3
Do not place
anything between
Incorrect Installation
1
weld cable terminal
and copper bar.
Summary of Contents for PipePro XC
Page 57: ...OM 269631 Page 51 269 637 D...
Page 58: ...OM 269631 Page 52 Figure 8 2 Circuit Diagram For XC RMD Wire Feeder CE...
Page 59: ...OM 269631 Page 53 269 639 A...
Page 70: ...Notes...