OM-246 466 Page 26
4-2. Front Panel Controls (See Section 4-3)
.
When an LED is lit, it means the related function is active.
1
Program Display
Displays the number of the active program.
2
Adjust Knob
Turn the Adjust knob to change program
number, Setup, Arc Control, and weld
parameters.
Panel/Remote amperage control is set for
each individual program. When set to remote,
the control range is from minimum to the value
set on the front panel.
3
Program Pushbutton LED
The LED lights when the Program Pushbutton
is active.
4
Program Pushbutton
Press button (LED lights) and turn Adjust knob
to select active program.
The letter C is displayed with the program
number if the program has been changed from
the factory settings using the optional PDA
with PipePro Program Management software
(PipeProMgr).
.
The program cannot be changed through
the front panel while welding.
Press and hold button to see program name.
Custom programs are named using optional
PDA with PipePro Program Management
software (PipeProMgr). Program name is
shown in upper and lower displays (items 13
and 15).
5
Setup Mode Indicators
The lit LED indicates which setup mode is
active. Setup mode parameters are shown in
Display Windows (see Items 13 and 15).
Process LED
When this LED is lit, turn the Adjust knob to
select the desired weld process. Choices
include MIG welding (displayed as MIG),
RMD-Pro (displayed as RMD), stick welding
(displayed as STIK), and lift TIG welding
(displayed as LIFT TIG).
Wire Type LED
When this LED is lit, turn the Adjust knob to
select the desired wire type, wire alloy, and
size. Wire type and size choices vary
according to the selected weld process.
Choices may include steel (displayed as
STL), stainless steel (SS), metal core
(MCOR). See Table 4-1 for all wire
abbreviations.
Gas Type LED
When this LED is lit, turn the Adjust knob to
select the desired weld gas. Gas type choices
vary according to the selected weld process.
See Table 4-1 for all gas abbreviations.
6
Setup Push Button LED
The LED lights to indicate one of the setup
modes is active.
7
Setup Pushbutton
Press button to select Process, Wire Type,
Wire Diameter, or Gas Type parameters.
.
In order for selections to be retained in
memory, the Setup pushbutton must be
pressed up to six times before any other
button is pressed. The displays will
temporarily show “PROG LOAD” to
indicate the data is being stored in
memory.
200 410
1
3
5
7
2
9
10
11
14
15
4
12
13
6
8
16