OM-246 466 Page 22
3-14. Motor Control Receptacle Functions
D
H
B
E
K
F
J
A
C
G
Ref. 803 675-A
Socket
Socket Information
A
Not used.
B
+40 volts dc.
C
Not used.
D
+40 volts dc return.
E
Not used.
F
Not used.
G
Electrode sense.
H
Not used.
J
Not used.
K
Not used.
3-15. Remote 14 Receptacle Information
A
J
B
K
I
C L N
H
D M
G
E
F
Ref. 804 374-A
Socket
Socket Information
A
+40 volts dc with respect to socket G.
G
Circuit common for +40 volts dc circuit.
B
Contact closure to socket K completes contactor control
circuit.
K
Contact closure to socket B completes contactor control
circuit.
C
+10 volts dc input from power source to wire feeder with
respect to socket D.
D
Remote volt control circuit common.
E
0 to +10 volts dc remote volt/trim signal from wire feeder to
power source with respect to socket D.
H
Voltage feedback; 0 to +10 volts dc, 1 volt per 10 arc volts.
F
Current feedback; 0 to +10 volts dc, 1 volt per 100 amperes.
M
0 to +10 volts dc remote WFS signal from wire feeder to power
source with respect to socket N, 1 volt per 100 IPM. When
doing Stick (SMAW) or TIG (GTAW) welding, the 0 to +10 volts
dc is a scale of the power source front panel setting.
N
Remote WFS control circuit common.
I
Remote process select A.
J
Remote process select B.
L
Electrode sense.
Summary of Contents for OM-246 466B
Page 14: ...OM 246 466 Page 10...
Page 63: ...OM 246 466 Page 59 Notes...
Page 65: ...OM 246 466 Page 61 243 024 B...
Page 74: ...Notes...