OM-240 113 Page 24
SECTION 6
−
OPERATION
O
6-1. Remote Panel
239 661-1-A
1
Alpha
−
Numeric Display
During the start sequence, the following
appears:
SYSTEMon
GLOWPLUG
GLOWdone
CRANKING
NO CRANK
See Section 6-3 for error messages that
appear.
2
Engine Status LED
Lights when display is showing engine re-
lated information.
3
Compressor Status LED
Lights when display is showing com-
pressor related information.
4
Engine Off LED
Lights when engine is off.
5
Engine Shutdown LED
Lights when display is showing an engine
error.
6
Compressor Shutdown LED
Lights when display is showing a com-
pressor error.
7
Power/Start Push Button
Press and release to cycle display until
display reads GLOWPLUG. When display
reads GLOWdone, press and hold to start
engine.
Press and release to turn on power to the
display only. This allows access to the dis-
play menu.
With engine running, press and release to
toggle between low speed and high speed.
The display will flash HIGH SPd when en-
gine is locked in high speed.
8
Engine Off Push Button
Press when engine is running to stop en-
gine.
9
Compressor On/Off Push Button
When engine is running, press twice to
turn compressor on or off.
When engine is not running, Press and re-
lease to display MinPRESS. Press and
hold to increment minimum pressure set-
ting.
.
Compressor minimum pressure is set
through the control program. Com-
pressor maximum working pressure is
set at the Air Pressure Regulator
(P
−
PRV). See Section 7-1.
10 Status Select Push Button
Press and release to cycle through the fol-
lowing displays:
RPM
Current fuel usage (Gallons Per Hour)
Engine hours
Engine maintenance hours (Counts down
from 400 hours)
Engine temperature
Compressor hours
Compressor maintenance hours (Counts
down from 500 hours)
.
Current fuel usage is for reference
only. Variables such as ambient tem-
perature, altitude and fuel blend affect
actual usage.
1
2
6
3
4
5
7
8
9
10
6-2. Safety Interlock (Models With Hydraulic Power Source)
The safety interlock system must be engaged before the EnPak engine can be started Contact dealer for detailed description of supplied system.
.
Test safety interlock monthly, see Section 8-4.