OM-252 624 Page 37
5-15. Making Single Operator CC Weld Connections
Welder A (Left) Side
Ref. 251 340-A / Ref. 802 292-A
!
Stop engine.
NOTICE
−
Do not exceed machine duty
cycle.
Welder B (right) weld output terminals
are disabled in Single Operator mode.
Connect only to Welder A (left) termi-
nals for Single Operator mode opera-
tion.
Use Single Operator mode for CC weld-
ing only. Welder B weld output termi-
nals are disabled in Single Operator
mode. (see Section 6-2).
See Section 5-16 for proper cable size.
1
Electrode Holder Cable
2
Work Cable
For Stick/TIG welding Direct Current Elec-
trode Positive (DCEP), connect work cable
to Negative (
−
) terminal and electrode hold-
er cable to Positive (+) terminal.
For Stick/TIG Direct Current Electrode Neg-
ative (DCEN), connect work cable to Posit-
ive (+) terminal and electrode holder cable
to Negative (
−
) receptacle.
Be sure Process Selector switch is set
correctly. See Section 6-3.
Tools Needed:
3/4 in.
Welder B (right) Terminals
Inactive In Single Operator Mode
1
2
Optional Weld Selector switch shown.
Direct Current Electrode Positive
(DCEP) connections are shown.