Soak Function
When type is set to Soak, the following screen appears on the display:
Mode.......: Custom Program
Segment....: 1
Type.......:>Soak
Soak Time..: 00:01:00
Custom Program Screen
Use the Cursor
button to move the cursor to the Soak Time position and use the Increase
or Decrease
button to set
the desired value.
When the cursor is in the Soak Time position, pressing the Cursor
button again automatically advances the program to the next segment
number.
End Function
When type is set to End, the following screen appears on the display:
Mode.......: Custom Program
Segment....:> 2
Type.......: End
Control TC.: 1
Custom Program Screen
The only changeable parameter in the End segment is selecting the number of thermocouples. Use the Cursor
button to move the cursor
to the Control TC position. Press the Increase
or Decrease
button to select the number of control thermocouples to be used for
the program. Selections are as follows: 1, 1,2, 1,2,3, or 1,2,3,4. TC1
MUST
always be a control thermocouple. TC2 thru TC4 can be used for
controlling or monitoring. When a thermocouple is selected as control, the LED adjacent to the seven-segment display illuminates.
A custom program can contain up to 10 segments. To view Program parameters, position the cursor at segment and use the Increase
or
Decrease
button to advance through the segment numbers until the End segment. When a segment number is changed, appropriate
segment parameter information appears on the display.