OM-222 166 Page 29
Mode.......: Custom Program
Segment....: 1
Type.......: End
Control TC.: 1
Custom Program Screen
The default position of the cursor is next to Segment. Press the Increase
or Decrease
button to increase or decrease the
segment number, unless the segment type is End. In this case, the segment number will advance to segment 1.
Use the Cursor
button to move the cursor to the desired selection (Type or Control TC), and press the Increase
or Decrease
button to change the value to the desired setting. When the cursor is moved to the Type selection, pressing the Increase
or
Decrease
button changes the segment type to Step, Ramp, Soak, or End. The functions of each segment type are as follows:
S
Step increases the temperature in the part at full-programmed power. A maximum temperature of 1450
°
F
(788
°
C) can be programmed.
S
Ramp increases or decreases the temperature in the part at a controlled rate in degrees per hour. A
maximum temperature of 1450
°
F (788
°
C) and a maximum rate of 9999
°
F/hr (5555
°
C/hr) can be
programmed.
S
Soak will hold the temperature for a programmed time. A maximum hold (soak) time of 99:59
(hours:minutes) can be programmed.
S
End is programmed to indicate the completion of the cycle and termination of output power.
Step Function
When type is set to Step, the following screen appears on the display:
Mode.......: Custom Program
Segment....: 1
Type.......:>Step
Temperature: 600
Custom Program Screen
Use the Cursor
button to move the cursor to the Temperature position and the initial temperature can be adjusted using the Increase
or Decrease
button.
Pressing the Cursor
button again automatically advances the program to the next segment number.
Ramp Function
When type is set to Ramp, the following screen appears on the display: