TM-428 Page 29
Miller Legend
6-13. Optional Remote Capacitor Board PC5 Testing Information Effective With Serial No.
KD346698
Ref. ST-800 698-A / SA-156 026-C
Be sure plugs are secure before
testing. See Section 6-14 for spe-
cific values during testing.
1
Capacitor Board PC5
2
Remote 14 Receptacle RC1
3
Receptacle RC2
4
Terminal K
Test Equipment Needed:
4
3
1
2
6-14. Optional Remote Capacitor Board PC5 Test Point Values Effective With Serial No.
KD346698
PC5 Voltage Readings
a) Tolerance –
±
10% unless
specified
b) Reference – to circuit com-
mon (lead 33) unless noted
Receptacle
Pin
Value
RC1
A
Contact closure to pin B completes the dc contactor control circuit
B
+15 volts dc output
C
Command reference, +4.5 volts dc output
D
Remote control circuit command
E
Input command signal from potentiometer wiper, 0 to +4.5 volts dc input
K
Chassis ground (lead 33)
RC2
1
Remote control circuit common
2
Command reference, +4.5 volts dc input
3
+15 volts dc input
4
Command signal from potentiometer wiper, 0 to +4.5 volts dc output
5
Not used
6
Contact closure to pin 3 completes contactor control circuit
Terminal
K
Chassis ground (lead 33)
Summary of Contents for Legend AEAD-200LE
Page 4: ......
Page 18: ...TM 428 Page 14 Miller Legend NOTES...
Page 49: ...TM 428 Page 45 Miller Legend SD 168 051 B...
Page 66: ...Notes...
Page 67: ...Notes...
Page 68: ......