OM-4405 Page 11
3-4.
Volt-Ampere Curves for CC/CV Models
202 655 / 202 656 / 202 654
The volt-ampere curves show the
minimum and maximum voltage
and amperage output capabilities of
the welding generator. Curves of all
other settings fall between the
curves shown.
A. Stick Mode
B. MIG Mode
C. TIG Mode
0
10
20
30
40
50
60
70
80
90
100
0
50
100
150
200
250
300
350
400
450
500
DC AMPERES
DC VOL
TS
Ranges
50 – 335
40 – 240
25 – 150
0
20
40
60
80
100
0
100
200
300
400
500
600
700
800
900
DC VOL
TS
Ranges
Max
DC AMPERES
0
20
40
60
80
100
0
100
200
300
400
500
600
700
800
900
1000
DC AMPERES
DC VOL
TS
MAX
MIN
150 – 420
40 – 90
75 – 200
110 – 315
15 – 75