OM-4405 Page 32
7-3.
Optional Auxiliary Power Receptacles
2
1
120 V 20 A AC GFCI
Receptacle GFCI1
2
240 V 16 A AC European
Receptacle RC1
3
240 V 15 A AC Australian
Receptacle RC1
4
240 V 15 A AC South African
Receptacle RC1
Receptacles supply 60 Hz single-
phase power at weld/power speed.
If a ground fault is detected, the
GFCI Reset button pops out and
the receptacle does not work.
Check for faulty tools plugged in
receptacle. Press button to reset
GFCI1.
At least once a month, run en-
gine at weld/power speed and
press test button to verify GFCI
is working properly.
5
Circuit Breaker CB2
6
Circuit Breaker CB3
CB2 protects GFCI1 from overload.
If CB2 opens, GFCI1 does not
work. Place button to reset breaker.
CB3 protects RC1 from overload. If
CB3 opens, RC1 does not work.
Press button to reset breaker.
If a circuit breaker continues to
open, contact Factory Autho-
rized Service Agent.
Auxiliary power is not affected
by weld output.
Maximum output is 2.4 kVA/kW
from GFCI1 and 4 kVA/kW from
RC1. Maximum output from all re-
ceptacles is 4 kVA/kW.
EXAMPLE: If 13 A is drawn from
RC1, only 7 A is available at GFCI1:
(240 V x 13 A) + (120 V x 7 A) =
4.0 kVA/kW
1
5
191 624
3
1
4
1
6
5
6
5
6
European Receptacle
Australian Receptacle
South African Receptacle
Summary of Contents for Big 40 WG
Page 29: ...OM 4405 Page 25 Notes...
Page 37: ...OM 4405 Page 33 SECTION 8 MAINTENANCE TROUBLESHOOTING 8 1 Maintenance Label...
Page 51: ...OM 4405 Page 47 Notes...
Page 53: ...OM 4405 Page 49 201 991 A...
Page 54: ...OM 4405 Page 50 Figure 9 2 Circuit Diagram For CC CV Welding Generator...
Page 55: ...OM 4405 Page 51 201 992 A...
Page 63: ...OM 4405 Page 59 Notes...