OM-210 540 Page 43
7-11. Diagnostic LED’s On Automation Interface Module PC9
LED
Status
Diagnosis
1
On
Input signal On from robot for jog advance
Off
Input signal Off from robot for no jog advance
2
On
Input signal On from robot to energize contactor
Off
Input signal Off from robot to not energize contactor
3
On
Input signal On remote program A selected
Off
Input signal Off remote program A not selected
4
On
Input signal On remote program C selected
Off
Input signal Off remote program C not selected
5
On
Input signal On from E-stop board PC12 for no emergency stop
Off
Input signal Off from E-stop board PC12 acknowledges E-stop is On from robot
6
On
Spare 1 not assigned
Off
Spare 1 not assigned
7
On
Input signal On Autoset-C selected
Off
Input signal Off Autoset-C not selected
8
On
Input signal On Autoset-B selected
Off
Input signal Off Autoset-B not selected
9
On
Input signal On Remote Jog on from peripheral plug
Off
Input signal Off Remote Jog off from peripheral plug
10
On
Input signal On Remote Purge on from peripheral plug
Off
Input signal Off Remote Purge off from peripheral plug
11
On
Input signal On from robot for jog retract
Off
Input signal Off from robot for no jog retract
12
On
Input signal On from robot for purge
Off
Input signal Off from robot for no purge
13
On
Input signal On remote program B selected
Off
Input signal Off remote program B not selected
14
On
Input signal On Touch Sensor on from robot or peripheral plug
Off
Input signal Off Touch Sensor off from robot or peripheral plug
15
On
Spare 0 not assigned
Off
Spare 0 not assigned
16
On
Spare 2 not assigned
Off
Spare 2 not assigned
17
On
Input signal On Autoset-A selected
Off
Input signal Off Autoset-A not selected
18
On
Input signal On Autoset-D selected
Off
Input signal Off Autoset-D not selected
19
On
Input signal On Remote Retract on from peripheral plug
Off
Input signal Off Remote Retract off from peripheral plug
20
On
Input signal On Remote Water Flow on from peripheral plug
Off
Input signal Off Remote Water Flow off from peripheral plug
21
On
Input signal On from robot for no emergency stop
Off
Input signal Off from robot for emergency stop
23
On
Input signal On from relay K3 for welding power source ready and no detected errors present
Off
Input signal Off from relay K3 for welding power source not ready, detected errors are present, or unit is
in operating mode preventing the weld ready signal from being enabled
Summary of Contents for Auto-Axcess 450
Page 14: ...OM 210 540 Page 10...
Page 51: ...OM 210 540 Page 47 Notes...
Page 53: ...OM 210 540 Page 49 207 903 G Part 1 Of 2...
Page 54: ...OM 210 540 Page 50 Figure 8 2 Circuit Diagram For Welding Power Source Part 2 Of 2...
Page 55: ...OM 210 540 Page 51 207 903 G Part 2 Of 2...
Page 56: ...OM 210 540 Page 52 Figure 8 3 Circuit Diagram For 72 Pin Robot Interface...
Page 57: ...OM 210 540 Page 53 219 266 C...
Page 58: ...OM 210 540 Page 54 Figure 8 4 Circuit Diagram For Peripheral Motor Interface...
Page 59: ...OM 210 540 Page 55 219 267 B...