OM-210 540 Page 38
7-3.
Removing Cover and Measuring Input Capacitor Voltage
Turn Off welding power source, and
disconnect input power.
Remove cover
1
Power Interconnect Board
PC2
2
Voltmeter
Measure the dc voltage across the
+ bus terminal and − bus terminal on
PC2 as shown until voltage drops to
near 0 (zero) volts. Measure input
capacitor voltage on both inverter
assemblies before proceeding.
3
Typical Bleeder Resistor
An example of a typical bleeder
resistor is shown on this page.
Proceed with job inside unit.
Reinstall cover when finished.
Tools Needed:
5/16 in
802 985 / Ref. 803 250-C
!
900 Volts dc can be present on the capacitor bus and
significant DC voltage can remain on capacitors
after unit is Off. Always check the voltage on both
inverter assemblies as shown to be sure the input
capacitors have discharged before working on unit.
1
2
+ lead to left bus terminal, − lead to right bus terminal
1
2
+ lead to left bus terminal, − lead to right bus terminal
3
Typical Bleeder Resistor
#16 AWG 1000 volts dc
insulation rating, approx
3 in (76 mm) leads
25 to 1000 ohm, 5
watt resistor
Summary of Contents for Auto-Axcess 450
Page 14: ...OM 210 540 Page 10...
Page 51: ...OM 210 540 Page 47 Notes...
Page 53: ...OM 210 540 Page 49 207 903 G Part 1 Of 2...
Page 54: ...OM 210 540 Page 50 Figure 8 2 Circuit Diagram For Welding Power Source Part 2 Of 2...
Page 55: ...OM 210 540 Page 51 207 903 G Part 2 Of 2...
Page 56: ...OM 210 540 Page 52 Figure 8 3 Circuit Diagram For 72 Pin Robot Interface...
Page 57: ...OM 210 540 Page 53 219 266 C...
Page 58: ...OM 210 540 Page 54 Figure 8 4 Circuit Diagram For Peripheral Motor Interface...
Page 59: ...OM 210 540 Page 55 219 267 B...