OM-4421 Page 37
7-4. Remote Voltage/Amperage Control On CC/CV Models (Optional)
1
Remote 14 Receptacle RC14
Connect optional remote control to
RC14 (see Section 5-11).
0774 / Ref. 215 158 / Ref. 803 602
Example: Combination Remote Amperage Control (Stick)
Adjust Optional Remote Control
Set V/A
Adjust Switch
Set Range
Control Not
Used In Remote
Stick Mode
Set Remote
Process
Example: Combination Remote Amperage Control (TIG)
Adjust Optional Remote Control
Set V/A
Adjust Switch
Set Range
Set Control
Set Remote
Process
1
In Example:
Process = Stick (Using Remote On/Off)
Range = 115 to 320 A DC
Min = 115 A DC
Max = 320 A DC
Max (320 A DC)
Min (115 A DC)
In Example:
Process = TIG (Using Remote On/Off)
Range = 35 to 250 A DC
Percentage Of Range = 50%
Min = 35 A DC
Max = About 143 A DC (50% of 35 to 250)
Max (143 A DC)
Min (35 A DC)