OM-4421 Page 17
4-4. Volt-Ampere Curves For CC/CV Models
215 080-A / 215 083-A / 215 079-A
The volt-ampere curves show the
minimum and maximum voltage
and amperage output capabilities of
the welding generator. Curves of all
other settings fall between the
curves shown.
A. Stick Mode
B. MIG Mode
C. TIG Mode
DC VOL
TS
DC AMPERES
DC VOL
TS
DC AMPERES
DC VOL
TS
DC AMPERES
100
80
60
40
20
0
0
100
200 300 400 500 600 700
800 900 1000
100
80
60
40
20
0
0
100
200 300 400
500 600 700 800
900 1000
MAX
MIN
100
80
60
40
20
0
0
100
200
300
400
500
RANGES:
MAX
155
−
450
115
−
320
75
−
195
40
−
90
RANGES:
60
−
365
35
−
250
25
−
155
15
−
75
Summary of Contents for 500 X