background image

4K 8x8 HDMI Matrix Switcher-N

 

26 

There is a blank screen on 
the display when switching 

The 

display 

does 

not 

support  the  resolution  of 
the video source. 

Switch again. 

Manage  the  EDID  data 
manually  to  make  the 
resolution  of  the  video 
source 

automatically 

compliant  with  the  output 
resolution. 

Cannot  control  the  device 
by  control  device  (e.g.  a 
PC) through RS232 port 

Wrong connection 

Check 

to 

ensure 

the 

connection  between  the 
control device and the unit 

Wrong RS232 
communication parameters 

Type in correct RS232 
communication 
parameters: Baud 
rate:9600; Data bit: 8; Stop 
bit: 1; Parity bit: none 

Broken RS232 port 

Send it to authorized 
dealer for checking. 

Static  becomes  stronger 
when  connecting  the  video 
connectors 

Bad grounding 

Check  the  grounding  and 
make  sure  it  is  connected 
well. 

Cannot  control  the  device 
by  RS232  /  IR  remote  / 
front panel buttons 

The device has already 
been broken. 

Send it to authorized 
dealer for repairing. 

If your problem persists after following the above troubleshooting steps, seek further 
help from authorized dealer or our technical support. 

Summary of Contents for MP-HD-88A-N

Page 1: ...MP HD 88A N 4K 8x8 HDMI Matrix Switcher N All Rights Reserved Version MP HD 88 N_2016V1 0 User Manual...

Page 2: ...reproduced without prior written consent FCC Statement This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause...

Page 3: ...or install this product near water Do not put any heavy items on the extension cable in case of extrusion Do not remove the housing of the device as opening or removing housing may expose you to dang...

Page 4: ...ation of RS232 Control Software 5 4 2 2 Basic Settings 5 4 2 3 RS232 Communication Commands 6 4 2 4 EDID Management 10 4 2 4 1 Via RS232 commands 10 4 2 4 2 Via 4 pin EDID DIP switcher 11 4 3 TCP IP C...

Page 5: ...4K 8x8 HDMI Matrix Switcher N 6 Panel Drawing 24 7 Troubleshooting Maintenance 25 8 After sales Service 27...

Page 6: ...0p 3D compliant with lower HDMI standards HDCP2 2 compatible HDMI output ports support HDMI 1 4 capable to transmit 2560x1080 60Hz signal compliant with lower HDMI standards HDCP1 4 compatible Transmi...

Page 7: ...l IR IN input port for IR control signal connect with IR receiver RS232 Serial control port connect with control device EDID Switcher 4 pin EDID DIP switchers to set EDID data 1 stands for On 0 stands...

Page 8: ...3 3 Connection Procedure Step1 Connect HDMI sources e g DVD to HDMI INPUTs with HDMI2 0 cables Step2 Connect HDMI displays e g HDTV to HDMI OUTPUTs with HDMI cables Step3 Connect speakers amplifiers t...

Page 9: ...s As its good performance in control and transmission the MP HD 88A N can be widely used in computer realm monitoring large screen displaying conference system television education and bank securities...

Page 10: ...es and output devices Then connect it with a PC installed RS232 control software Double click the software icon to run this software Here we take the software CommWatch exe as example The icon is show...

Page 11: ...Locked Unlock Unlock the front panel buttons System Unlock Version Inquire the firmware version VX X X MessageOff Turn off command feedback from the com port It will only show simple words like SWITCH...

Page 12: ...Clear F1 EDIDG x Get EDID data from output x and display it on com port EDIDM X B y Enable input x to learn the EDID data from output y If the EDID data is not available the matrix will set it to init...

Page 13: ...DID data from output x to input y If the EDID data is available and the audio part supports not only PCM format then force set it to only support PCM If the EDID data is not available it will set to i...

Page 14: ...sable the SPDIF audio output of single output port x 9 disable the SPDIF audio output of all output ports DigitAudio OFF with Output 4 Inquiry Commands Status x Check the input channel for output x AV...

Page 15: ...Y Y Out 5 6 7 8 Audio N N Y Y 4 2 4 EDID Management MP HD 88A N provides with convenient EDID management to create effective communication between the display and sources In factory default status Sta...

Page 16: ...pin EDID DIP switcher Beside EDID can be managed via RS232 commands MP HD 88A N boasts a 4 pin EDID DIP switcher to manage EEID Dial the switchers to invoke demanded EDID data Embedded EDID data 10 se...

Page 17: ...s 192 168 0 178 Gateway is 192 168 0 1 and Serial Port is 8080 IP can be changed as you need Serial Port cannot be changed Controlled by single PC Connect a computer to the TCP IP port of the MP HD 88...

Page 18: ...88A N Do please remember the PC s original network segment Step3 Set the MP HD 88A N s network segment to the same as the router Step4 Set the PC s network segment to the original one Step5 Connect t...

Page 19: ...b based GUI In addition to control MP HD 88A N via communication software 8x8 The Matrix Switcher can be controlled via web based GUI It allows users to interact with the Matrix Switcher through graph...

Page 20: ...nistrator mode User name admin Password admin default setting User mode User name user Password user default setting Note Log in as admin can access more configuration interfaces than user Here is a b...

Page 21: ...etween every input and output users can carry on the connections by clicking corresponding button Buttons 1 8 at the right bottom corner provides quick saving and recall for overall connection status...

Page 22: ...following interface Figure 4 11 Copy EDID The EDID of INPUT device can be gained from OUTPUT devices Step1 Select one OUTPUT device that you want to copy its EDID Step2 Select one or more input device...

Page 23: ...re 4 12 Audio EDID 2 Status 1 At the top of the interface click Status to enter the following interface to modify the name and mode of this machine and then they will be display in LCD screen Figure 4...

Page 24: ...following interface to modify the name of scenes Figure 4 15 Status Scene 3 Network At the top of the interface click Network to enter the following interface to inquire and configure network setting...

Page 25: ...17 Password In the above interface turn on the Front Panel to lock all buttons of machine they cannot be operated 4 3 4 TCP IP Configuration IP address subnet mask and Gateway of MP HD 88A N can be mo...

Page 26: ...e 4 18 TCP IP Configuration 4 3 5 GUI Update GUI for MP HD 88A N supports online update in http 192 168 0 178 100 Type the username and password the same as the GUI log in settings modified password w...

Page 27: ...88A N to enter upgrade mode Press and hold button 2 3 when rebooting The power indicator will keep blinking in upgrade mode Step3 Double click the icon of upgrade software DfuSe Demonstration see the...

Page 28: ...l DTS DTS HD Max Resolution 4Kx2K 1080P 3D Transmission Distance 4Kx2K 60Hz 15m Power Supply DC 24V 2 5A Power Consumption 32W Full Load 2 2W Standby Dimension W H D 437 x 44 x 235 mm Weight 1 96Kg Te...

Page 29: ...3 4 5 6 7 8 1 2 3 4 5 6 7 8 TCP IP On Off 1 2 3 4 1 0 IR IN RS232 EDID FIRMWARE INPUTS OUTPUTS CONTROL SPDIF SPDIF SPDIF SPDIF SPDIF SPDIF SPDIF SPDIF DC 24V ON DIP Tx Rx 44 mm 23 mm 436 mm 32 mm SYST...

Page 30: ...her input source or enable the display to learn the EDID data of the input No output on the amplifiers connected to audio output ports The amplifiers are not able to decode HDMI audio Change for ampli...

Page 31: ...device and the unit Wrong RS232 communication parameters Type in correct RS232 communication parameters Baud rate 9600 Data bit 8 Stop bit 1 Parity bit none Broken RS232 port Send it to authorized dea...

Page 32: ...or removed from the product Damage deterioration or malfunction caused by Normal wear and tear Use of supplies or parts not meeting our specifications No certificate or invoice as the proof of warrant...

Reviews: