3.6.4 Alarm Output
Alarm Output function is supported by UI-5016-B, UI-7016-B, UI-7032-B, UI-8032-B, UI-5016-PB, and
UI-7032-PB.
Step 1. Set Alarm output channel, Alarm Name, Alarm Type and Record Channels.
Alarm Output No.: The channel which will output the alarm signal.
Alarm Name: Set a name for the alarm.
Alarm Type: Choose NO or NC alarm type for the alarm.
Dwell Time: The output time for alarm. If the output alarm lasts too long, you can select the Manually
Clear to stop it.
Step2. Select effective Time for alarm output.
The user can set effective schedule as following two ways:
①
Select the operation type: AlarmOut or Erase. Then drag a square on the time table for time
setting, it will be more convenient by clicking
or
to set or clear all time
settings.
②
Click
to edit record effective time manually.