42
2.2 Sensor Settings
2.2.1 Hardware Overview
2.2.2 Hardware Installation
Please deploy the sensors above each parking space.
1. Ensure the location of device is within the communication range of LoRaWAN
®
gateway and keep it away from metal objects.
2. Device must be sat in a horizontal position on top of the object so that it has a clear
path to the object. And the detection distance of the sensor is
up to 450cm
from the
object, so please install the sensor within this range.
3. Place device in where it is far away from the side-wall more than 30 cm and without
internal obstructions that block the ultrasonic signal. If the device has to install on the
side wall, please ensure the ultrasonic sensor direction point away from the wall.