27
Basic Packet Composition
SIG
COMMAND
DATA_SIZE
DATA
SIG END
2 byte
2 byte
4 byte
Variable
2 byte
COMM_LOGIN_REQ
1. Data Type: JSON-charset=utf-8
2. Data Content: ID and Password
3. Example
{
“id”: “admin”,
“password”: “1234”
}
SIG
COMMAND
DATA_SIZE
DATA
SIG END
2 byte
2 byte
4 byte
Variable
2 byte
CC FF
0x0001
Variable
JSON DATA
FF DD
※
DATA_SIZE = DATA 2 bytes(SIG END)
※
Use Little-Endian