background image

4

Access for servicing

Before carrying out any maintenance, make sure the 
fi replace is turned off including the pilot.

MAKE SURE THE FIREPLACE IS COLD!

Accessing the fan

1. 

Access the fan from the rear of the fi rebox.

a)  Remove the front, trim, and other accessory 

necessary to have access to the gas valve 
on the left hand side of the appliance and the 
window. See the instruction manual supplied 
with the appliance.

b)  Below the gas valve, turn the switch off (O) so 

the fi replace does not start accidentally.

c)  Detach the vent plate from the top of the 

fi replace (2 screws) and slide it out of the 
fi rebox.

d)  Pull the appliance out of the cavity. You need 

access to the left-hand side and the rear of the 
appliance.

2. 

Remove the left side valve access panel (5 

screws).

Disconnect

fan control

wire from

receiver

Fan

control

wire

3. 

Disconnect the fan from electric power.

4. 

Carefully disconnect the fan control wire from the 

receiver.

5. 

At the rear of the appliance, remove the fan box (9 

screws).

You can now clean the fan enclosure and the fan cavity 
at the back of the appliance. Take this opportunity to 
clean the back of the appliance as well.

WARNING

TO AVOID ELECTRIC SHOCK 

TO AVOID ELECTRIC SHOCK 

disconnect the 

disconnect the 

power to the fan before servicing.

power to the fan before servicing.

WARNING

!

WARNING

WARNING

DO NOT TOUCH THE FIREPLACE WHILE IT IS 

DO NOT TOUCH THE FIREPLACE WHILE IT IS 
HOT! 

HOT! 

Let it cool fi rst before any maintenance.

Let it cool fi rst before any maintenance.

WARNING

!

Summary of Contents for Valor 795CFKV2

Page 1: ... gas and removing the heater form the cavity The fan is designed for automatic operation to come on and off when the burner comes on and off The fan speed can be controlled from the remote control handset There are four speeds available The fan if turned on will start approximately 4 minutes after lighting the appliance and will continue to run for approximately 10 minutes after the burner is shut...

Page 2: ... depth of the appliance 1 Fit the fan to the appliance a On the back of the appliance remove the sheet metal plate 9 screws and discard it b Apply the self adhesive wiring diagram label provided at the back of the fan enclosure as shown 6 foot electrical cord Fan control wire module to receiver Wiring diagram Fan control module Fan enclosure c Remove the left side valve access panel 5 screws d Unp...

Page 3: ...e On the remote control handset s display the icon represents the fan and the icon represents the speed The fan has four speeds settings One bar is start low four bars is high no bar is off 1 On the remote handset briefly press the SET button repeatedly to scroll to the fan mode The fan icon flashes 2 Press the large flame button to activate the fan function and increase its speed Press the small ...

Page 4: ...eed access to the left hand side and the rear of the appliance 2 Remove the left side valve access panel 5 screws Disconnect fan control wire from receiver Fan control wire 3 Disconnect the fan from electric power 4 Carefully disconnect the fan control wire from the receiver 5 At the rear of the appliance remove the fan box 9 screws You can now clean the fan enclosure and the fan cavity at the bac...

Page 5: ...hreaded nuts as this allows the fan to be tight within the enclosure to avoid any vibration when functioning 2 Removing the fan control module The module is held in place by a piece of Velcro Disconnect the power the fan and the receiver connectors to release the module Note Grab the whole connector when disconnecting DO NOT pull on the wires 3 Reconnect and reinstall the module and the fan after ...

Page 6: ...a properly grounded three prong receptacle Do not cut or remove the grounded prong from this plug Designed and Manufactured by for Miles Industries Ltd 190 2255 Dollarton Highway North Vancouver B C CANADA V7H 3B1 Tel 604 984 3496 Fax 604 984 0246 www valorfireplaces com Because our policy is one of constant development and improvement details may vary slightly from those given in this publication...

Page 7: ... le bouton SET plusieurs fois jusqu à ce que l icône du ventilateur apparaisse et clignote Appuyez sur les deux boutons des flammes pour régler la vitesse indiquée par l icône Aucune barre noire sur l icône de la vitesse indique que le ventilateur est arrêté et ne fonctionnera pas automatiquement Le ventilateur est réglé lorsque l icône cesse de clignoter Les icônes du ventilateur et de la vitesse...

Page 8: ...TO TH IS KIT AN D SH OU LD ON LY BE RE PL AC ED WITH OR IG IN AL EQ UI PM EN T WIRI NG FR OM TH E MAN UF AC TU RE R VIS DE MISE À LA TE RR E CO RD ON ÉL EC TR IQ UE DE 6 PIED S 1 9 M MIS À LA TE RR E BO ÎTIER DU VE NT ILAT EU R 40 04 22 7 01 MOD UL E DE CO MMAN DE VE NT ILAT EU R RÉ CE PT EU R DE TÉ LÉ CO MMAN DE FO UR NI AV EC LE FO YE R NO TE LE FILA GE ET LE S BO RN ES SO NT SP ÉC IFIQ UE S À C...

Page 9: ...écran de la manette l icône représente le ventilateur et l icône représente la vitesse d opé ration Le ventilateur a quatre vitesses Une barre indique la mise en marche et la basse vitesse quatre barres indiquent la vitesse la plus rapide Aucune barre indique que le ventilateur n est pas en fonction 1 Sur la manette appuyez brièvement plusieurs fois sur le bouton SET et défilez jusqu à ce que l ic...

Page 10: ...u d accès à la soupape sur le côté gauche 5 vis Débranchez le fil de commande du ventilateur au récepteur Fil de commande du ventilateur 3 Débranchez le ventilateur du courant électrique 4 Débranchez soigneusement le fil de commande du ventilateur au récepteur 5 À l arrière de l appareil enlevez le boîtier du ventilateur 9 vis Vous pouvez maintenant nettoyer le ventilateur son boîtier et la cavité...

Page 11: ...u en place par une pièce de Velcro Débranchez les bornes du cordon d alimentation POWER du ventilateur FAN et le fil du module au récepteur Notez Débranchez les bornes à pince NE TIREZ PAS SUR LES FILS 3 Rebranchez et réinstallez le module de commande s il a été débranché ou déplacé pour l entretien 4 Réinstallez le boîtier du ventilateur en le fixant au panneau arrière de l appareil 9 vis 5 Faite...

Page 12: ...9 M MIS À LA TERRE BOÎTIER DU VENTILATEUR 4004227 01 MODULE DE COMMANDE VENTILATEUR RÉCEPTEUR DE TÉLÉCOMMANDE FOURNI AVEC LE FOYER NOTE LE FILAGE ET LES BORNES SONT SPÉCIFIQUES À CE KIT ET NE DEVRAIENT ÊTRE REMPLACÉS QUE PAR DE L ÉQUIPEMENT ORIGINAL DU MANUFACTURIER BORNES MOLEX VENTILATEUR MODÈLE 795CFKV2 VENTILATEUR DE CIRCULATION D AIR 120 VAC 60 HZ MOINS D UN AMPÈRE FABRIQUÉ POUR MILES INDUSTR...

Reviews: