Miles Industries HORIZON 535XAN Installation & Operating Instructions Manual Download Page 5

55

State of California. Proposition 65 Warning. 

Fuels used in gas, wood-burning or oil fired appliances, and the products 

of combustion of such fuels, contain chemicals known to the State of California to cause cancer, birth defects and other 

reproductive harm. California Health & Safety Code Sec. 25249.6.

State of Massachusetts Carbon Monoxide Detector/Vent Terminal Signage Requirements

For all side wall horizontally vented gas fueled equipment installed in every dwelling, building or structure used in whole or 

in part for residential purposes, including those owned or operated by the Commonwealth and where the side wall exhaust 

vent termination is less than seven (7) feet above finished grade in the area of the venting, including but not limited to 

decks and porches, the following requirements shall be satisfied: 

1. INSTALLATION OF CARBON MONOXIDE DETECTORS. At the time of installation of the side wall horizontal vented 

gas fueled equipment, the installing plumber or gas fitter shall observe that a hard wired carbon monoxide detector with 

an alarm and battery back-up is installed on the floor level where the gas equipment is to be installed. In addition, the 

installing plumber or gas fitter shall observe that a battery operated or hard wired carbon monoxide detector with an 

alarm is installed on each additional level of the dwelling, building or structure served by the side wall horizontal vented 

gas fueled equipment. It shall be the responsibility of the property owner to secure the services of qualified licensed 

professionals for the installation of hard wired carbon monoxide detectors.

a. In the event that the side wall horizontally vented gas fueled equipment is installed in a crawl space or an attic, the hard 

wired carbon monoxide detector with alarm and battery back-up may be installed on the next adjacent floor level.

b. In the event that the requirements of this subdivision can not be met at the time of completion of installation, the owner 

shall have a period of thirty (30) days to comply with the above requirements; provided, however, that during said thirty 

(30) day period, a battery operated carbon monoxide detector with an alarm shall be installed.

2. APPROVED CARBON MONOXIDE DETECTORS. Each carbon monoxide detector as required in accordance with the 

above provisions shall comply with NFPA 720 and be ANSI/UL 2034 listed and IAS certified. 

3. SIGNAGE. A metal or plastic identification plate shall be permanently mounted to the exterior of the building at a 

minimum height of eight (8) feet above grade directly in line with the exhaust vent terminal for the horizontally vented gas 

fueled heating appliance or equipment. The sign shall read, in print size no less than one-half (1/2) inch in size, “GAS 

VENT DIRECTLY BELOW. KEEP CLEAR OF ALL OBSTRUCTIONS”.

4. INSPECTION. The state or local gas inspector of the side wall horizontally vented gas fueled equipment shall not 

approve the installation unless, upon inspection, the inspector observes carbon monoxide detectors and signage installed 

in accordance with the provisions of 248 CMR 5.08(2)(a)1 through 4. 

(b) EXEMPTIONS: The following equipment is exempt from 248 CMR 5.08(2)(a)1 through 4: 

1. The equipment listed in Chapter 10 entitled “Equipment Not Required To Be Vented” in the most current edition of NFPA 

54 as adopted by the Board; and 

2. Product Approved side wall horizontally vented gas fueled equipment installed in a room or structure separate from the 

dwelling, building or structure used in whole or in part for residential purposes. 

(c) MANUFACTURER REQUIREMENTS - GAS EQUIPMENT VENTING SYSTEM PROVIDED. When the manufacturer 

of Product Approved side wall horizontally vented gas equipment provides a venting system design or venting system 

components with the equipment, the instructions provided by the manufacturer for installation of the equipment and the 

Safety and Warning Information

Summary of Contents for HORIZON 535XAN

Page 1: ...s appliance is suitable for installation in a bedroom or bed sitting room Manufactured by MILES INDUSTRIES LTD British Columbia Canada www valorfireplaces com Installation Operating Instructions Do no...

Page 2: ...d by Dealer Name _______________________________________ Phone Number ______________________________________ Should you encounter an operational problem call your dealer immediately Do not try to repa...

Page 3: ...Installations with Horizontal Termination Installing to Wall 23 Installations with Vertical Termination Through the Roof 25 Remote Control Installation 26 Gas Supply Installation 27 Aeration Setting C...

Page 4: ...THER vent system or components MAY BE USED This gas fireplace and vent assembly MUST be vented directly to the outside and MUST NEVER be attached to a chimney serving a separate solid fuel burning app...

Page 5: ...oor level b In the event that the requirements of this subdivision can not be met at the time of completion of installation the owner shall have a period of thirty 30 days to comply with the above req...

Page 6: ...uirements shall be satisfied by the manufacturer 1 The referenced special venting system instructions shall be included with the appliance or equipment installation instructions and 2 The special vent...

Page 7: ...primarily for post installation conversion in areas where natural gas was not available at the time of initial installation Venting options Direct vent installations solid piping A list of all approv...

Page 8: ...Stand offs 7 180 mm From finished wall front to top vent 2 50 mm min From combustible framing to vent Stand offs 4 1 2 114 mm 1 1 2 38 mm 16 406 mm Dimensions Figure 1 Major dimensions clearances with...

Page 9: ...nnel should install these appliances These appliances when installed must be electrically grounded in accordance with local codes or in the absence of local codes with the National Electrical Code ANS...

Page 10: ...1 2 23 cm x 90 2 cm immediately above the opening area shown hatched in Figure 4 which must be constructed with non combustible materials such as cement board Wall Finish 29 3 4 to Wall Finish 38 3 4...

Page 11: ...ble components The location requirements are shown in the table and graph below and figure 5 14 36 cm max combustible wall A B C D E F G H 1 0 2 3 4 5 6 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 FORBIDDE...

Page 12: ...pipe lengths will be required A thimble kit may also be necessary See venting accessories list on pages 36 37 for allowable components Horizontal Termination Corner Location 45 Pipe Run See figures 5...

Page 13: ...tructions supplied with the termination unit 2 The venting system for these appliances is considered to be a Special Venting System The rule in the Natural Gas and Propane Installation Code CAN CGA B1...

Page 14: ...tical vent terminal cap or a low profile vertical termination Zero Clearance stand offs and shields supplied with the heater are not required for this application Flashing 2 x 3 liners 2 x 3 liners Co...

Page 15: ...event condensation on window 12 30 D Vertical clearance to ventilated soffit located above the terminal within a horizontal distance of 2 feet 60 cm from the center line of the terminal 18 46 E Cleara...

Page 16: ...4 Wood screws for fixing appliance to studding 1 Deluxe remote control 601SFB Standard Metal Front alternative 1 Upper louver unit 1 Lower louver unit 2 Side channels 2 Hinge studs 2 Hinge spacers 2 M...

Page 17: ...r Louver Hinge Spacers Magnet Counterplates Hinge Studs Top Casting Bottom Casting Styrofoam Support Vent Pipe Terminal 12 Thread cutting Screws Wall Shields Wall Plates 8 Wall Plugs 8 Wood Screws Top...

Page 18: ...and turn counterclockwise through the IGN position to PILOT A spark should flash across from the pilot electrode to the pilot shield 817VAK Pipe Adapter Fitting See figure 14 1 Fit the adapter 817VAK...

Page 19: ...Instructions may vary as 556CLA may be installed on top or back of heater depending on heater model See Figure 14b 1 Remove blank plate and gasket to gain access to exhaust spigot Retain plate and goo...

Page 20: ...tand offs and shield supplied with the heater are not required for the co linear application Support Angles Fitting See figure 17 The distance from the wall angles to the front face of the heater case...

Page 21: ...as far as possible and tighten the screws over the restrictors To set the restrictors at minimum port opening slide the restrictors up as far as possible and tighten the screws Installations with Hor...

Page 22: ...The top support angle should abut the cement board but is not fixed to the framing 3 Check the wall finish requirements with the homeowner If necessary adjust the position of the heater so that the di...

Page 23: ...a 10 x 10 square If the wall is totally non combustible e g masonry block or concrete mark for a 7 circular hole In both cases the center of the hole should line up with the center line of the horizo...

Page 24: ...mbustible fit wall thimbles Install as detailed in the manufacturer s instructions supplied with the pipes Sidewall vent terminations within 7 of grade require a terminal guard when used with a 551DVK...

Page 25: ...a plumb from the roof to the small hole in the ceiling and mark the roof at this spot If rafters or other obstructions will prevent a vertical exit or if clear attic space is desired the roof outlet c...

Page 26: ...ness plug Connect wires A with the L terminals to the connectors B on the control valve as shown below Please note that the L connectors are different sizes the smaller one fits to the lower connectio...

Page 27: ...iance must be isolated from the gas supply piping system by closing its individual manual shut off valve during any pressure testing of the gas supply piping system at test pressures equal to or less...

Page 28: ...the burner See figure 35 2 Place the rear log in position locating the two pins in the top of the wedge into the holes in the rear log See figure 36 3 Place the front log at the front of the firebox...

Page 29: ...switch inside the appliance and the remote control hand unit See Lighting Instructions further on in this manual for full details Aeration adjustment As described on page 27 burner aeration is adjusta...

Page 30: ...firebox sides See figure 45 2 Attach the top casting unit by hooking it over the four tabs at the firebox sides See figure 46 Additional Optional 3 or 4 Sided Trims 1 Slide a corner connection plate...

Page 31: ...ft and unhook the two side channels See figure 51 Open the bottom louver it does not need to be removed Cast Iron Front Lift up and unhook the upper casting The bottom casting does not need to be remo...

Page 32: ...l be helpful if the appliance serial number can also be quoted This is on the rating plate which is on a chained plate accessible by opening the bottom access panel The repair parts are shown in the s...

Page 33: ...mperature Setting the temperature Use this setting when you come in and want to enjoy a specific temperature 1 Push the AUTO button until a number and F flash Let go 2 While it is still flashing push...

Page 34: ...hold it until P1 appears and flashes Let go While flashing push the buttons hour and minutes to set the time at which you want your fireplace to turn on in the morning 4 Press the TIMER button and hol...

Page 35: ...water 1 STOP Read the safety information above 2 Set the flame adjustment knob as far clockwise as possible 3 Turn the gas control knob clockwise to OFF NOTE The knob cannot be turned from PILOT to OF...

Page 36: ...Vent Adapters Couplers Universal Adapter 3 Flex Coupler 2150 TM CFAA3 Co linear Flex Connector 46DVA ADF Co axial to Co linear Adapter 46DVA GCL TM 4CAA 556CLA Co linear to Co axial Adapter 46DVA GK...

Page 37: ...46DVA FF TF 4F SV4F 559FSK Masonry Flashing TF 4MF Various Venting System Parts Wall Thimble 46DVA WT 4DT WT TM 4WT SV4RSM Storm Collar 46DVA SC 4DT SC TM SC SV4AC Decorative Plate 46DVA DC 4DT CS TM...

Page 38: ...on for air from other household equipment or appliances iii Damage due to chemicals dampness condensation or sulphur in the fuel supply lines which exceeds industry standards i This warranty does not...

Reviews: