12
12
Horizontal Side Termination
See figures 5 & 6.
The vent pipe dimensional requirements in section
Horizontal Rear Termination
apply.
The minimum floor location is shown in figure 6.
Can be used with either #551DVK standard vent kit
or another terminal cap and accessories. Adapter
#817VAK, one 90° vent elbow and pipe lengths will
be required. See venting accessories list on pages
36–37 for allowable components.
Horizontal Side or Rear Snorkel
Termination
The vent pipe dimensional requirements in sections
Horizontal Rear Termination
and
Horizontal Side
Termination
apply.
Adapter #817VAK, one 90° vent elbow, a snorkel
termination and pipe lengths will be required. A
thimble kit may also be necessary. See venting
accessories list on pages 36–37 for allowable
components.
Horizontal Termination, Corner Location,
45° Pipe Run
See figures 5 & 7.
The vent pipe dimensional requirements in section
Horizontal Rear Termination
apply.
The minimum corner location is shown in figure 7.
Can be used with either #551DVK standard vent kit
or another terminal cap and accessories. Adapter
#817VAK, one 90° vent elbow and pipe lengths will
be required. See venting accessories list on pages
36–37 for allowable components.
6-1/8” (156 mm)
min.
to hole center
14” (36 cm)
max.
combustible
wall
16-1/2”
(42 cm)
min.
Figure 6
1-1/2” (38 mm) min.
clearance
1-1/2” (38 mm) min.
clearance
14” (36 cm) max.
combustible
wall
45-7/8”
(117 cm)
min.
10-7/8”
(276 mm)
min.
45-7/8” (117 cm) min.
64-3/8”
(164 cm) min.
Figure 7
Location