MIKOTERM eCompact Plus 12kW Manualbook For Installation, Handling And Maintenance Download Page 6

 
 

 

2.7 

Minimum 

distances 

and 

burnable 

construction materials 

 
Depending  on  valid  regulations,  other  minimum  distances 
could be applied, different than mentioned below.

 

 



Comply with regulations of electrical installations and 

       minimum distances which are in force in the subject  
       country

 

 



Minimum distance for heavy inflammable and self- 

       extinguishing materials is 200 mm

 

 

 

Inflammability of components

 

 

A

 

 

Non-inflammable

 

 

 

A1:

 

 

Non-inflammable

 

 

 

Asbestos, stone, wall tiles, baked 
clay, plaster (with no organic 
additives)

 

 

A2:

 

 

With smaller 

quantity of 
added 
elements 
(organic 
components)

 

 

Plaster cardboards plates, base 
felt, glass fibres, plates of 
ACUMIN, ISOMIN, RAIOT, 
LOGNOS, VELOX, AND 
HERACLITUS 

 

 

B

 

 

Inflammable

 

 

B1:

 

 

Hardly inflammable

 

 

Beech, oak, veneered wood, felt, 
HOBREX,

 

VERSALIT and

 

UMAKART plates 

 

B2:

 

 

Normally 
inflammable

  

Pine, larch and spruce,

 

veneered 

wood

 

B3:

 

 

Inflammable

  

Asphalt, cardboard, cellulose 
materials, tar-paper, plywood 
plates,

 

cork plates, polyurethane, 

polystyrene,

 

polyethylene, floor 

fibre materials

 

 

Table  2:

 

Ignitable  materials  and  composition  of  elements 

according to DIN 4102 

 
 
 
 
 
 
 
 
 
 
 
 

 
 
 

 

2.8

 

Product description 

 
Basic components of boiler: 

  Boiler body 

 

  Device frame and casing 

 

 

Control unit

 

 

 

Pump

 

 

 

Expansion dish (8

l

)

 

 

  Processor board and boiler electronics 

 

 

Water pressure sensor

 

 

 

Safety valve

 

 

 

Boiler can be installed as integral part of the central heating system, 
floor heating, hybrid, or accumulation systems

 
 

Boiler  is  compounded  of  weld  housing  of  steel  tin  with  thermal 
insulation. The boiler is fixed on the wall by supplied mounting set. 
Installed heating insulation in boiler jacket reduces loss of the heat, 
and also protects against noise

 

Safety  elements  (vent  valve,  managing  surface  fuse  and 
temperature safety limitation) are mounted at the top of boiler

 

Depending  on  the  type  of  the  boiler,  different  elements  of 
heating  are  used.  Heating  elements’  performance  can  be 
adjusted according to grades

 

Different  performance  grades  sets  can  be  obtained  through 
control panel. Number and division of performance grades are 
visible from technical data (see chapter 

2.12.2). 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

Device data

  

Summary of Contents for eCompact Plus 12kW

Page 1: ...Guidebook for installation handling and maintenance ENG eCompact Plus Electric block boiler for heating systems with thermoregulatory microprocessor FG eCompactPlus 01 2020...

Page 2: ...on air emission 5 Electrical connection 5 1 Positions of introducer for the introduction of the power cable 5 2 Connecting power voltage cable 5 3 Scheme for connecting power voltage cable 5 4 Connect...

Page 3: ...assembly All electric works should be performed by authorised person in accordance with corresponding regulations Commissioning and maintenance and repairs should be done by authorised service only Te...

Page 4: ...o spare parts not delivered by the manufacturer Use only original spare parts Material damages due to freezing When there is damage due to freezing drain water from the boiler tank and pipelines for h...

Page 5: ...ax pressure of 2 6bar which should be controlled on regular basis Boiler should be handled only by adults who are familiar with instructions and work of the boiler Do not close safety valve Inflammato...

Page 6: ...lyurethane polystyrene polyethylene floor fibre materials Table 2 Ignitable materials and composition of elements according to DIN 4102 2 8 Product description Basic components of boiler Boiler body D...

Page 7: ...nt 11 Automatic fuses with voltage trigger 12 Terminal for room thermostat 13 Microprocessor plate 14 Heater relay 9 18kW contactor 24 27kW 15 Temperature sensor 16 Safety thermostat STB 17 Control pa...

Page 8: ...is damaged during delivery Check if delivery is complete Part Pieces Boiler eCompact Plus 1 Assembly Set 1 Instructions for handling 1 2 11 Factory plate Factory data plate is placed on the external...

Page 9: ...2 12 Dimensions and technical data 2 12 1 Dimensions and technical data for boiler Image 2 Dimensions and connection Device data...

Page 10: ...cable cross section for three phase power supply mm 5 2 5 5 2 5 5 4 5 4 5 6 5 6 Needed fuses for single phase supply voltage A 1 32 1 50 Minimum cable cross section for single phase power supply mm 3...

Page 11: ...carts for bags with tighten strip The product should be in horizontal position during transportation Avoid shocks or collisions Packed boiler put on carts for bags if needed secure it with strip and...

Page 12: ...ulations and local laws Electric connector should be done according to the connecting plans After corresponding installation of device execute grounding of the plant Before opening device and all work...

Page 13: ...dowel enclosed in device packaging or adequate dowel for unusual kind of wall Then screw bolts into delivered dowels or other in such way that are left out from the wall min 5 mm max 10mm Carefully ha...

Page 14: ...shines near the mark bar 4 7 1 Filling the boiler with heating water and sealing test Waterproof should be tested prior to put on the boiler 1 Check pre pressure of expansion dish If is pressure leve...

Page 15: ...set is on lower side below of device They are on lower plate of device in the back left corner image 6 It is intended for connecting device when power cable comes from the lower side of the boiler II...

Page 16: ...nnected to three pole fusses L1 L2 and L3 When introducing a power cable into the boiler through any selected set of glands carefully patch the cable to the three pole automatic fuses to avoid damagin...

Page 17: ...of digital programmable room thermostat with battery supply Image 9 Scheme of boiler connecting on three phase power supply Image 8 Scheme of boiler connecting to single phase power supply ONLY FOR P...

Page 18: ...boiler of 12 18kW 3 2667W for boiler of 24kW 3 3000W for boiler of 27kW G3 Heater 3 2000W for boiler of 18kW 3 2667W for boiler of 24kW 3 3000W for boiler of 27kW LCTR 2 Microprocessor thermoregulato...

Page 19: ...Electric connecting Image 12 Boiler electric scheme eCompact Plus with nominal power of 6kW...

Page 20: ...Electric connecting Image 13 Boiler electric scheme eCompact Plus with nominal power of 9kW and 12kW...

Page 21: ...Electric connecting Image 14 Boiler electric scheme eCompact Plus with nominal power of 18kW 24kW and 27kW...

Page 22: ...on Prior to turn on check if heating installation is filled with water and air vent Turn on main switcher below device Heating system and device parameters will appear on display Device is adjusted by...

Page 23: ...l 7 2 2 Basic adjustments The current temperature is continuously displayed on the display indicating the LED that is lit beside the Temp mark To display other parameters use the keys and In addition...

Page 24: ...Each touch to the button will increase decrease given temperature of the boiler for 1 C Working temperature range is 10 C 80 C Confirmation of change must be done by pressing button SET If change is...

Page 25: ...urns off all heaters and pump delayed for 2 min and pressure measuring indicator starts to flash quickly Display still shows present temperature of the boiler image 19 It is necessary to reduce pressu...

Page 26: ...ays for 2 min and temperature measuring indicator will flash quickly image 22 With this temperature value there is danger of freezing and boiler damage so the work of this device will be blocked To co...

Page 27: ...T 100 C display of its value is not possible to see on the screen so in this will appear code EH meaning that temperature is T 100 C image 26 Measuring temperature indicator will continue to flash qui...

Page 28: ...g T 2 C or upper limit T 89 C of temperature of the heating system Measure Turn off electric power supply for the boiler Call service Graphic display of the area of blockade of the boiler work conditi...

Page 29: ...manufacturer instructions 7 3 8 Heating discontinuity With short time discontinuity of heating working regime the boiler temperature must be decreased using thermo regulator of the boiler To prevent...

Page 30: ...elivered by the manufacturer Control examination log is provided on chapter 8 4 Perform works in accordance with log on control and maintenance All deficiencies remove immediately 8 1 Boiler cleaning...

Page 31: ...heck if there is any damage on electric duct lines 6 Check if electric control connections and used elements are fitted tighten it if needed 7 Check thermo regulator on boiler 8 Check function of safe...

Page 32: ...economy concepts we use only the best technique and materials Packaging Regarding packaging we respect system of recycling which is specific in certain states and which secure optimal recycling All m...

Page 33: ...amaged Check all three phases Check set power of boiler Change damaged part Change damaged part Boiler heats but it is very noisy Higher level of noise during work Air in the system Small water flow P...

Page 34: ...lector Button settings 9 Drain faucet Wilo Para MSL 6 43 SC is a circulating pump for heating systems heating systems for family houses and other similar systems The most important characteristics of...

Page 35: ...ess and hold the operating button for atleast 4 seconds All LEDs flash for 1 second The LEDs for the last setting flash for 1 second Decommissioning Shutting down the pump Shut down the pump immediate...

Page 36: ...precautions for assembly installation and maintenance are described in the operating and installation instructions Read and follow the operating and installation instructions 10 All of the data that...

Page 37: ...Note...

Page 38: ...cted by intellectual property of MIKOTERM d o o Any unauthorized use copying or publication in whole or in part by other entities without the authorization of MIKOTERM d o o is punishable by law Nis 2...

Reviews: