User’s manual for Remote Unit MOR801B Power
M0070A0A.doc
Id.-No 151155
Page 53
18-June-99
A VT100 terminal or a PC with VT100 emulation can be connected to the control module
SM2009 by a standard RS232 cable, if necessary in connection with an adapter 9 to 25.
Cable Connections PC - Control Module SM2009
9 contact SUB - D- Connector
9 contact SUB - D- Connector
male
male
PC
RS 232
MOR801B Power
PIN
PIN
1 )
( 1
2 )
( 2
3 )
( 3
4 )
( 4
5 )
( 5
6 )
( 6
7 )
( 7
8 )
( 8
9 )
( 9
The following communication mode between control module and VT100 is set initially.
9600 baud - 8 bit - no parity -1 stopbit
These settings can only be changed after connection of the terminal.
Modifications are possible by software commands.
Note:
Settings on the Repeater can be performed after the following procedure
only.