5
|
MIJAR
–
WATER TREATMENT |
| Azotowa 15b | 41-503 Chorz
ów |
Poland | Tel./fax. 32 2899674 | email: [email protected] | www.mijar.eu |
The system is configured to use 4,5 kg of reagent per each regeneration.
Calculating the amount of softened water between regenerations:
The amount of water between regenerations is calculated according to this formula:
Z = 9000x10/y
Where
Z
–
is the amount of softened water between regenerations
Y
–
x w ‘ (G )
An example of calculation the amount of
f w ‘z’ w .
D : x w = 5’
f ‘z’ w w f :
Z = 9000 x 10/15 = 6000 liters.
A w f 5’GH w
6000 liters of softened water.
TAB. 1. CAPACITY
–
Maxi Elegant B65
Water Hardness
English
degree
French
degree
PPM
German
degrees
Efficiency
Maxi
Elegant
12,5
18,0
178,6
10
9000
13,8
19,8
196,5
11
8182
15,0
21,6
214,3
12
7500
16,3
23,4
232,2
13
6923
17,5
25,2
250,0
14
6429
18,8
27,0
267,9
15
6000
20,0
28,8
285,8
16
5625
21,3
30,6
303,6
17
5294
22,5
32,4
321,5
18
5000
23,8
34,2
339,3
19
4737
25,0
36,0
357,2
20
4500
26,3
37,8
375,1
21
4286
27,5
39,6
392,9
22
4091
28,8
41,4
410,8
23
3913
30,0
43,2
428,6
24
3750
31,3
45,0
446,5
25
3600
32,5
46,8
464,4
26
3462
33,8
48,6
482,2
27
3333
35,0
50,4
500,1
28
3214
36,3
52,2
517,9
29
3103
37,5
54,0
535,8
30
3000
38,8
55,8
553,7
31
2903
40,0
57,6
571,5
32
2813
41,3
59,4
589,4
33
2727
42,5
61,2
607,2
34
2647
43,8
63,0
625,1
35
2571
45,0
64,8
643,0
36
2500
46,3
66,6
660,8
37
2432
47,5
68,4
678,7
38
2368
48,8
70,2
696,5
39
2308
50,0
72,0
714,4
40
2250
The stated capacities were calculated based on standard application and machine conditions. This information
may vary according to external influencing factors (for example, fluctuating raw water quality).