MiHome MIHO001 Manual Download Page 4

Mi

 

Home

 

 

 

 

 

 

 

 

 

 

     

 

 

   

 

 

  

 

 

 

   

 

 

 

 

 

 

 

  

 

 

 

 

 

 

 

 

  

 

 

   

 

 

 

 

 

 

 

 

 

 

 

 

 

 

   

 

 

   

 

 

 

 

 

 

 

 

 

LN

220-240V ~50Hz
Max. 13A µ
Resistive Load
Frequency 433.92 MHz
BS1363

Link to Earth

 

Terminal in

 

metal box

Mi

 

Home

MiHome Double Wall Sockets

Fitting and Wiring Instructions
1). Before commencing work, isolate the mains power supply and remove the fuse in the fuse box or switch on the circuit 
breaker in the consumer unit.
2). If unit is to be used as a replacement for an existing product, remove existing unit from its location and disconnect the 
wiring. The back box will need to be at least 35mm deep 
otherwise the original will need to be replaced.
3). This item will not t into a 4 lug box. If such a box has been previously installed the top and bottom lugs should be 
removed or bent back to avoid contact with the interior.
4). Connect the wires as shown in appropriate wiring diagrams above. Use green/ yellow sleeving on earth conductors that 
are not insulated. Ensure terminals are properly tightened and no bare wire is visible. Push back unit into mounting box 
making sure conductors are not trapped.
5). Screw the unit module to the mounting box, please ensure screws are suǸ ciently tight to support the product but please 
do not over tighten as this may cause some deformation.
6). If the product has a decorative front cover plate over the module, place the cover plate over the module and press î rmly 
on the top and bottom until all retaining clips have fully clipped into position. To remove the decorative front cover plate, 
carefully insert a 3 mm terminal screwdriver into the bottom slots and lift upward until all the retaining clips 
disengage from the plastic module moulding. Please ensure the decorative plate is held as it is released to avoid it being 
dropped and damaged.
7). To reduce the risk of discolouration or tarnishing, avoid installation on damp plaster.
8). These products must be installed in accordance with the latest Building and IET 
wiring regulations. If in any doubt, please contact a qualiî ed electrician.

Typical Installation

9

L             N