background image

ii

  

TS571W Installation Instructions

TS571W Installation Instructions

  

iii

CAUTION

The gate will move freely and uncontrolled when the gate operator is removed from the gate.  

ONLY disconnect the operator when the control box power switch is OFF and the gate is NOT moving.

BEFORE YOU BEGIN TO INSTALL YOUR AUTOMATIC GATE OPERATOR:

Read these instructions carefully to become familiar with all parts and installation steps. 

The video is only designed as an overview of the installation procedure. 

You must read the installation manual for detailed instructions 

on gate operator safety and proper use of the gate operator.

Please Read This First!

Thank you for purchasing a Mighty Mule Gate Operator—
Nortek Security and Control's "do-it-yourself" automatic 
gate operator! When correctly installed and properly used, 
your Mighty Mule Gate Operator will give you many years 
of reliable service. Please read the following information 
to ensure you have the correct system for your particular 
needs. If so, this manual and will enable you to properly 
install your Mighty Mule Gate Operator.
The Mighty Mule Gate Operator is designed for installation 
for single or dual gates. The gate(s) must not exceed 18 
feet in length or weigh more than 850 pounds (please see 
Technical Specifications on 

page x

). The Mighty Mule Gate 

Operator can be used on vinyl, aluminum, chain link, farm 
tube, and wrought iron gates. 

 Not rated for use on solid surface gates due to the 

potential to damage the operator and/or injure someone. 
The Mighty Mule Gate Operator accommodates extra 
transmitters, digital keypads, solar panels, push buttons, 
automatic gate locks, and other access control products. 
These optional accessories (see the Mighty Mule Accessory 
Catalog) are available at most stores. Your store should be 
able to special order any accessory not in stock. 
If your store cannot special order accessories, please call 
the Mighty Mule Sales Department (800-543-4283).
The Mighty Mule Gate Operator features Dual Sense 
Technology™. This feature makes the gate stop and 
reverse direction when it comes in contact with an 
obstruction. 

The Mighty Mule Gate Operator also has an adjustable 
auto-close feature. After the gate reaches the fully open 
position, it can be set to remain open up to 120 seconds 
before automatically closing. Pressing the transmitter 
button at any time after the gate opens fully will cause it 
to close immediately. OFF is the factory setting; meaning 
the gate will stay open until you press the transmitter (or 
keypad, etc.) again.
Visit 

www.mightymule.com

 for a retailer near you.

Clevis Pin

Hairpin Clip

Gate Bracket

Front  Mount

Because automatic gate operators produce high levels 
of force, consumers need to know the potential hazards 
associated with improperly designed, installed, and 
maintained automated gate operator systems. 

Keep in 

mind that the gate operator is just one component of 

the total gate operating system.

 Each component must 

work in unison to provide the end user with convenience, 
security, and safety.
This manual contains various safety precautions and 
warnings for the installer and end user. Because there are 
many possible applications of the gate operator, the safety 
precautions and warnings contained in this manual cannot 

Disconnecting the Operator

1.  Turn control box power switch OFF.
2.  Remove the hairpin clip and clevis pin.
3.  Remove the operator’s front mount from the gate bracket.

The gate can be opened and closed manually when the operator 
is disconnected.

be completely exhaustive in nature. It does, however, 
provide an overview of the safe design, installation, and 
use of this product. 

CAREFULLY READ AND FOLLOW ALL 

SAFETY PRECAUTIONS, WARNINGS, AND INSTALLATION 
INSTRUCTIONS TO ENSURE THE SAFE SYSTEM DESIGN, 
INSTALLATION, AND USE OF THIS PRODUCT. 

 Warnings in this manual are identified with this 

warning symbol. The symbol identifies conditions that can 
result in damage to the operator or its components, serious 
injury, or death.

MANUALLY OPENING AND CLOSING GATE

Because Mighty Mule automatic gate operators are only part of the total gate operating system, it is the responsibility 
of the installer and end user to ensure that the total system is safe for its intended use.

NOTE:

 Substitute a

 

Pin Lock

 for the clevis pin on the front mount of 

the gate operator to prevent theft of the operator from the gate (

see 

accessory pages in back of this book).

  

Important Safety Information

NOT FOR THE CONTAINMENT OF ANIMALS.

Part #: FM133

Summary of Contents for TS571W

Page 1: ...Manual Leading Edge of the gate Photo Beam recommended not included Photo Beam recommended not included Sensing Edges recommended not included Vehicular Gate Gate Warning Sign Control Box TS571W PRINT...

Page 2: ...ll to Open Operator Mounting Most Common 2 Installing the Closed Position Stop Plate Pull to Open 7 Push to Open Operator Mounting 8 Installing the Closed Position Stop Plate Push to Open 13 Control B...

Page 3: ...an adjustable auto close feature After the gate reaches the fully open position it can be set to remain open up to 120 seconds before automatically closing Pressing the transmitter button at any time...

Page 4: ...ey should be within sight of the gate located at least 10 feet from any moving part of the gate see diagram below Never install any control device where a user will be tempted to reach through the gat...

Page 5: ...43 4283 and requesting a duplicate copy FOR THE INSTALLER AND END USER FOR THE INSTALLER AND END USER Mighty Mule gate operators utilize Dual Sense Technology entrapment protection Dual Sense Technolo...

Page 6: ...tion and are required when installing Mighty Mule Automatic Gate Operators A minimum of two WARNING SIGNS must be installed in the area of the gate Each sign is to be visible by persons located on the...

Page 7: ...e 3 12 v single gate 10 watts solar charger 8 16 26 12 v single gate 20 watts solar charger 14 28 38 12 v single gate 30 watts solar charger 20 44 54 Power increments are for reference only Low fricti...

Page 8: ...uded Ground Ground 2 Inches or Less above ground Copper ground rod clamp Copper Single Conductor Lug 3 16 Drilled Pilot Hole 6 ft deep or more Metal gate post Metal Gate Post 12awg or Larger Gate Open...

Page 9: ...Weatherproof cover for outdoor outlet and transformer If the post is larger than 6 bolts longer than 8 are needed ITEMS NOT INCLUDED TOOLS NEEDED Mechanical Installation ASSESSING THE GATE FOR INSTAL...

Page 10: ...e recommended clearances TIP Turning the pivot bracket over gives more hole alignment options for the gate post pivot bracket assembly With the gate in the OPEN position use clamps to secure the opera...

Page 11: ...re securely clamped Secure the post pivot bracket in place by installing the hardware shown Tighten both bolts O and Q Remove the gate post and gate brackets Use a hammer and center punch to mark the...

Page 12: ...ence Post Remove the operator from the gate post and gate brackets With the gate fully open install the closed position stop plate hardware not included Do not fully tighten hardware until after the n...

Page 13: ...ate Ensure that the operator is level With the operator arm temporarily secured to the gate check to ensure there is at least 2 inches of clearance between the operator arm and gate See illustration i...

Page 14: ...OR MOUNTING PUSH TO OPEN OPERATOR MOUNTING Step 6 Step 5 Step 7 Step 8 Step 9 Secure the gate post bracket subassembly with the supplied hardware as shown Using a drill and 7 16 drill bit drill the ne...

Page 15: ...N N S S Secure the gate bracket with the supplied hardware as shown Once the gate post and gate brackets are installed reattached the operator arm Ensure the operator arm is level adjusting the post...

Page 16: ...ecurely tighten R OR R 3 Min 3 Min 4 Max Step 1 Step 2 Step 3 Note If you intend to install and use the MMS100 Wireless Connectivity System sold separately with your gate operator consider mounting yo...

Page 17: ...er Access Connect the battery power wires Red to Red BAT and Black to Black BAT CONNECTING THE OPERATOR AND BATTERY TRANSFORMER OR SOLAR PANEL WIRING INSTALLATION WARNING Before digging contact local...

Page 18: ...AUX SW1 SW2 PUSH 1 2 3 4 5 TERM6 GRN WHT BAT BAT GRN WHT BRN ORG BRN ORG RED BLK RED BLK AUX V AUX V PRIMARY SECONDARY SW1 SW2 TERM6 Battery Power Access From the other end of the low voltage wire st...

Page 19: ...is preset from the factory to Low If your operator stops and reverses during a normal cycle follow the instructions below to change the Stall Force setting Adjusting the Stall Force 1 Press and hold t...

Page 20: ...iring Accessories through Control Board Wiring Knockout Carefully remove wiring knockout plugs to insert accessory wires Open the control box cover Close the control box cover Insert accessory wires t...

Page 21: ...OT apply external voltage inputs to these terminals All ACCESSORY INPUTS ITEMS 2 6 are connected with respect to the COMMON terminals ITEM 1 LOCK OUTPUTS ACCESSORY INPUTS CONTROL BOARD CONNECTIONS Pho...

Page 22: ...struction detection devices if the unit works troubleshoot these devices h h Arm rev counter h h Arm power cable connections 1 beep every 10 seconds Low battery condition h h Check Fuses h h Battery H...

Page 23: ...Connect battery batteries Visual Feedback Possible Diagnosis Check Solution The unit will not run 1 Unit arm travel limit not set 2 Transmitter not programmed 3 Power source issues 4 Arm problem h h...

Page 24: ...f repair or replacement of your gate operator is necessary the Service Department will assign a Return Authorization RA number 5 Include a copy of your receipt and securely pack the component s author...

Page 25: ...rity and Control unless otherwise indicated All rights are reserved by Nortek Security and Control and content may not be reproduced downloaded disseminated published or transferred in any form or by...

Page 26: ...TER CODE on the MM136 keypad 1 2 3 4 is the default unless changed Once learned LED2 will flash and the buzzer will sound on the gate operator control board Proceed with installation of the MM136 per...

Page 27: ...tallation Instructions Telephone Mighty Mule Sales 1 800 543 4283 Fax 850 575 8912 or Mighty Mule Technical Service 1 800 543 1236 Fax 850 575 8950 www mightymule com Copyright 2019 Nortek Security an...

Reviews: