background image

 

MM660 Installation Instructions

  

36

POWER IN LED

CHARGING LED

ON

Steady ON

Battery Charging

ON

Blinking

Battery Fully Charged

ON

OFF

Test charging circuit, check battery

OFF

OFF

No AC/Solar Power, check battery

OFF

Blinking

Check battery, incoming AC transformer or solar

OFF

Steady ON

Test charging circuit and check incoming AC trans-

former or solar and check battery

15

FUSE

BATT+

BATT-

1  2  3  4

ON 

STATUS

LEARN  RMT

RECEIVER

LEARN

MAST  LIMIT 

LEARN

2ND  LIMIT 

S3

S4

ALM

S2

OFF

SOFT  START  OFF
WARNING       OFF
OPEN                PULL
2ND    OPEN     DLY.
MODE1               OFF
MODE2               OFF

ON
ON
PUSH
SIMULT.
ON
ON

120 MIN

MAX

CHARGING

POWER  IN

GTO   RCVR.

WHT

B

LU

BRN

O

RG

RED

BLK

GRN

WHT

B

LU

BRN

O

RG

RED

BLK

GRN

CO

M

GRN

BLK

RED

CY

CLE

SAFET

Y

EXIT

SHADO

W

OPEN EDGE

CO

M

LOCK

PWR

AUX

RLY

POWER

INPUT

CONTROL OUTPUTS

MASTER OPERATOR

2ND OPERATOR

CONTROL INPUTS

AUTO CLOSE  TIME 

STALL   FORCE

CL

OSE

EDGE

GTO 18 VOLT

TRANSF. OR

SOLAR  PANEL

1

2

3

4

5

6

7

DIAG

PORT

CHARGING

POWER  IN

RED LED

GREEN LED

Battery/Power Troubleshooting

If your Gate Operator is not operating properly, please follow the steps below:
 

1.  First use the procedures found in the Troubleshooting Guide (see page 25). 

 

2.   Use the 24/7 Troubleshooting Wizard at http://support.gtoinc.com.

 

3.  If you are unable to solve the problem, call the GTO Service Department at (800) 543-1236, or (850) 575-

4144.  Refer to the serial number (located on the right side of the control box) and date of purchase when 

calling for assistance.

 

4.   If repair or replacement of your gate operator is necessary, the Service Department will assign a Return 

Goods Authorization (RGA) number to you.

 

5.   Securely pack the component(s) authorized for return to the factory.  Include a copy of your sales receipt 

for the purchase of the product(s). Write the RGA number issued to you on the outside of the package in 

LARGE BOLD PRINT.  

 

 

Ship the package(s) freight prepaid to: GTO, 3121 Hartsfield Road, Tallahassee, Florida, USA 32303.

  NOTE: Products returned to GTO without a Return Goods Authorization (RGA) number in LARGE 

BOLD PRINT on the outside of the package WILL NOT be accepted.  Also, items returned to GTO 

freight collect WILL NOT be accepted.

Repair Service

GTO Technical Service and Installation Assistance

8:00am–7:00pm • Monday–Friday (EST)

Toll Free Support: 800-543-1236 • Fax: 850-575-8950

24/7 Troubleshooting Wizard: http://support.gtoinc.com

Summary of Contents for MM660

Page 1: ...in China for GTO Access Systems LLC Copyright 2016 GTO Access Systems LLC Document Number R66008 REV A 12 19 16 GTO Sales 800 543 4283 Fax 850 575 8912 GTO Technical Service 800 543 1236 For 24 hour...

Page 2: ...ntended to service the general public Vehicular Gate Operator Class Categories i WARNING This equipment meets Underwriters Laboratory Standard 325 UL 325 However gate equipment has hazards associated...

Page 3: ..._________________________ 19 Receiver Installation _____________________________________________________________20 Connecting the Battery___________________________________________________________ 21...

Page 4: ...tore should be able to special order any accessory not in stock If your store cannot special order accessories please call the Mighty Mule Sales Department 800 543 GATE The Mighty Mule Gate Operator f...

Page 5: ...They do however provide an overview of the safe design installation and use of this product CAREFULLY READ AND FOLLOW ALL SAFETY PRECAUTIONS WARNINGS AND INSTALLATION INSTRUCTIONS TO ENSURE THE SAFE S...

Page 6: ...zones for the type of installa tion An entrapment zone is an area around the automatic gate system where a person or object could be caught that increase the risk of injury Entrapment zones must be e...

Page 7: ...alled they should be within sight of the gate located at least 10 feet from any moving part of the gate see diagram below Never install any control device where a user will be tempted to reach through...

Page 8: ...D Always turn power to operator OFF before performing any maintenance See page 33 for maintenance procedures 7 To operate this equipment safely YOU must know how to disconnect the operator for manual...

Page 9: ...ransmits radio frequency RF signals to the gate operator for obstruction protection functions shall be located where the transmission of the signals is not blocked or impeded by building structures na...

Page 10: ...to promote pedestrian usage Locate the gate such that persons will not come in contact with the vehicular gate during the entire path of travel of the vehicular gate We recommend using the GTO Bulldo...

Page 11: ...Swing Gate Operator MM600 SERIES DC Swing Gate Operator P N MM660 Serial Number MM660 0000000 GTO Access Systems LLC Tallahassee Florida USA MMDDYY 9901178 Control Box label with Manual Open and Clos...

Page 12: ...a 120 Vac 18 Vac output trans former One lade style control board fuse is rated for 15 A NOTE The transformer should not be directly connected to any battery Do not replace fuses with higher ampere r...

Page 13: ...e wrought iron wood not recommended for solid surface gates Pull to Open Option Instructions begin on page 13 Push to Open Option Instructions begin on page 16 A Level B Plumb C Free Swinging For the...

Page 14: ...c l e s o n l y P e d e s t r i a n s m u s t u s e a s e p a r a t e e n t r a n c e M o v i n g G a t e C a n C a u s e I n j u r y O r D e a t h W A R N I N G I n st a l l a ti o n O ve rv i e w f...

Page 15: ...se both transformer and solar If you have thin walled tube or panel gates see Recommended Reinforcement Examples after Step 3 of Mounting Pull to Open Opener to Gate section page 13 Depending on the t...

Page 16: ...ate Bracket Thin Walled Tube Gate Gate Bracket 1 x 6 Wood Reinforcement Panel Gate Gate Bracket Wood or Metal Reinforcement not supplied Mounting Plate Created for Decorative Gate required but not sup...

Page 17: ...are OK Step 5 in both open and closed positions 9 8 Mark middle of post bracket slots on fence post Mark middle of gate bracket slots on gate cross support Remove clamps post bracket gate bracket and...

Page 18: ...ll bolts and remove excess length on post and gate bracket bolts with hacksaw 15 Your Property 2 1 1 2 Fully open gate Attach gate stop with one of the following U bolts tube and chain link gates Not...

Page 19: ...lf not supplied Gate Bracket Thin Walled Tube Gate Gate Bracket 1 x 6 Wood Reinforcement Panel Gate Gate Bracket Wood or Metal Reinforcement not supplied Mounting Plate Created for Decorative Gate req...

Page 20: ...s Mark middle of post bracket slots on fence post Mark middle of gate bracket slots on gate cross support 10 9 Remove clamps post gate brackets and opener Then use a hammer and center punch to dimple...

Page 21: ...gate bracket with hacksaw After the bolts are trimmed remove the opener from the gate 14 15 2 1 1 2 Closed Position Stop Plate Installation J 1 Fully open gate Attach gate stop on the outside of the g...

Page 22: ...X 1 2 3 4 5 6 7 WHT BLU BRN ORG RED BLK GRN MASTER OPERATOR 5 BLK WHT BLU BRN ORG RED BLK GRN COM CYCLE SAFETY EXIT SHADOW COM MASTER OPERATOR CONTROL INPUTS CLOSE EDGE 7 Correct Wrong Wrong 6 Secure...

Page 23: ...available as special order items call the Mighty Mule Sales Department NEVER splice receiver cable Run the cable through PVC conduit to protect it from damage DO NOT run cable through metal conduit b...

Page 24: ...6 feet of the control box Attach the battery harness wires from the control box to the battery terminals using bolts washers and nuts Be sure to attach the RED wire to the POSITIVE terminal and the BL...

Page 25: ...TOR 2ND OPERATOR CONTROL INPUTS AUTO CLOSE TIME STALL FORCE CLOSE EDGE 1 2 3 4 5 6 7 POWER INPUTS LOCK PWR AUX RLY CONTROL OUTPUTS GTO 18VOLT TRANSFORMER OR SOLAR Correct Wrong Wrong 14 SURGE PROTECTO...

Page 26: ...ar charging power prior to the battery depleting to a state where the unit will not function see accessory pages in back of this book The figures shown are for winter minimum sunlight and do not accou...

Page 27: ...COM COM MASTER OPERATOR 2ND OPERATOR AUTO CLOSE TIME 1 2 3 4 5 6 7 POWER INPUT LOCK PWR AUX RLY CONTROL OUTPUTS GTO 18VOLT TRANSFORMER OR SOLAR POWER INPUT LOCK PWR AUX RLY CONTROL OUTPUTS GTO 18VOLT...

Page 28: ...ed or closed position This saves wear and tear on the gate and gate opener system DIP Switch 2 Warning Buzzer The warning buzzer alerts you when the gate opener is beginning to either open or close th...

Page 29: ...o increase the stall force See page 28 Press and hold the LEARN MAST LIMIT button for 5 seconds or until the alarm sounds Press button on transmitter to fully open gate Closed limit is set upon reachi...

Page 30: ...er ON 1 2 3 2 1 1 2 3 4 ON LEARN MAST LIMIT LEARN 2ND LIMIT S3 S4 S2 OFF SOFT START OFF WARNING OFF OPEN PULL SLV OPEN DLY MODE1 OFF MODE2 OFF ON ON PUSH SIMULT ON ON 120 MIN MAX 3 2 4 1 Control Box S...

Page 31: ...nt of force the opener will apply against an obstruction before it stops and reverses direction The adjustment on the control board operates like a volume control on a radio It controls the amount of...

Page 32: ...usly for 5 seconds or until the alarm sounds Setting Personal Transmitter Code Remove back cover of the opener remote Flip opener remote over Use small screwdriver to move switch es to random position...

Page 33: ...ial installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communic...

Page 34: ...4 EXIT Typically for use with exit loop or wand Activation of this input will open the gate if it s not already at the open position Activation of this input while at open limit will restart the auto...

Page 35: ...sor NOTE Connections are for typical applications There may be additional connection options for applications that are not illustrated here 2 1 1 3 1 4 Mighty Mule Keypad 1 1 2 1 2 ABC 3 DEF 4 GHI 5 J...

Page 36: ...oting Maintenance Tips Monthly test the obstruction and entrapment protection systems Monthly service the gate operator make sure the power switch is OFF Clean extended operator arm with a soft dry cl...

Page 37: ...ry Under Load Battery Harness Connections A series of beeps that stop and do not repeat after power up Circuit Board Powered Up Ready Normal Operation Continuous Uninterrupted Alarm Circuit Board Sens...

Page 38: ...ge Terminal Shorted Disconnect the edge sensor photo beam or any other accessory wired to this terminal Try the remote If the remote works the problem is the accessory Status clear 6 blinks Open Edge...

Page 39: ...low 1 First use the procedures found in the Troubleshooting Guide see page 25 2 Use the 24 7 Troubleshooting Wizard at http support gtoinc com 3 If you are unable to solve the problem call the GTO Ser...

Page 40: ..._______________ Place of Purchase ____________________ Remember to keep all receipts for proof of purchase Converting Metric Units to English Equivalents When You Know Multiply By To Find Symbol centi...

Page 41: ...table code settings is standard equipment with all Mighty Mule systems battery is included Digital Keypad FM137 The specially designed digital keypad can be easily installed as a wireless or wired key...

Page 42: ...battery for the Mighty Mule FM560 FM502 gate operator systems This is the only battery approved for use with the Mighty Mule FM560 FM502 gate operator systems Life expectancy is 2 3 years Low Voltage...

Page 43: ...ns These signs must remain at all times 6 There are no controls installed on the gate operator or within 10 feet of the gate 7 The Dual Sense Technology feature has been properly adjusted and tested t...

Page 44: ...is open Monday Friday 8 00 A M 5 00 P M Eastern Time For technical service Call toll free 1 800 543 1236 The Mighty Mule Technical Service Department is open Monday Friday 8 00 A M 7 00 P M Eastern Ti...

Page 45: ......

Reviews: