27
MM560 Installation Instructions
With gate in CLOSED position, turn control box power switch
to ON.
Press button on opener remote; gate should start opening. Press but-
ton on opener remote again when gate is in desired OPEN position.
Press and hold the “LEARN MASTER LIMIT” button for 5
seconds, or until the alarm sounds.
Press button on opener remote to fully close gate. Open limit is
set upon reaching the fully closed limit. Test and, if needed reset
and start over.
ON
15
FUSE
B
AT
T+
B
AT
T-
1 2 3 4
ON
ST
A
TUS
LE
ARN RMT
RECE
IV
ER
LEARN
MA
S
T
LIMIT
LEARN
S
LV
LIMIT
S3
S4
ALM
S2
OFF
SOFT ST
A
R
T OFF
W
ARNING OFF
OPEN PULL
SL
V OP
EN DL
Y.
MODE1 OFF
MODE2 OFF
ON
ON
PU
SH
SI
MUL
T.
ON
ON
1
20
M
IN
MAX
CHAR
GING
PWR IN
GT
O R
CVR.
WHT
BLU
BRN
ORG
RED
BLK
GRN
WHT
BLU
BRN
ORG
RED
BLK
GRN
COM
GRN
BLK
RED
CYCLE
SAFETY
EXIT
SHADOW
OPEN
EDGE
COM
MASTER C
ABLE
SL
A
VE C
ABLE
C
ONTR
OL INPU
T
S
A
UT
O CL
OSE
TIME
ST
ALL FOR
CE
CLOSE
EDGE
1
2
3
4
5
6
7
PO
WER
INPUT
S
LOCK
PWR
AU
X
R
LY
C
ONTR
OL
OUTPUT
S
1
2
3
2
1
15
FUSE
B
AT
T+
B
AT
T-
1 2 3 4
ON
ST
A
T
US
LEAR
N RMT
RECEIVER
LEARN
MAST
LI
MI
T
LEARN
S
LV
LI
MIT
S3
S4
A
LM
S2
OFF
S
OFT
ST
AR
T
OFF
W
ARN
ING
OFF
OPEN
PU
LL
S
LV
OPEN
D
LY
.
MODE
1
OFF
MODE
2
OFF
ON
ON
P
USH
S
IMUL
T.
ON
ON
1
20
MIN
MA
X
GT
O R
CVR.
WHT
BLU
BRN
ORG
RED
BLK
GRN
WHT
BLU
BRN
ORG
RED
BLK
GRN
COM
GRN
BLK
RED
CYCLE
SAFETY
EXIT
SHADOW
OPEN
EDGE
COM
G
TO
TR
ANSF
LOCK
PWR
AU
X
R
LY
PO
WER
INPUT
S
C
ONTR
OL
INPUT
S
MAST
ER C
A
B
LE
SL
A
VE C
ABLE
C
O
NT
R
OL INP
U
T
S
A
UT
O CL
OSE
TIME
ST
ALL FOR
CE
CLOSE
EDGE
18 V
A
C
or
SOL
AR
G
TO
LOCK
AU
X
1
2
3
4
5
6
7
15
FUSE
B
AT
T+
B
AT
T-
1 2
3 4
ON
ST
A
TUS
LEA
R
N
RMT
RE
CEIVER
LEARN
MA
ST
LI
MIT
LEARN
S
LV
L
IM
IT
S3
S4
AL
M
S2
OFF
SOF
T S
TAR
T
OFF
W
ARNING
OFF
OPE
N
P
ULL
SL
V
OPEN
D
LY
.
MOD
E1
O
FF
MOD
E2
O
FF
ON
ON
PUS
H
SIMUL
T.
ON
ON
120
MIN
MA
X
GT
O R
CVR.
WHT
BLU
BRN
ORG
RED
BLK
GRN
WHT
BLU
BRN
ORG
RED
BLK
GRN
COM
GRN
BLK
RED
CYCLE
SAFETY
EXIT
SHADOW
OPEN
EDGE
COM
MASTER C
ABLE
SL
A
VE C
ABLE
C
ON
TR
OL INPUT
S
A
UT
O CL
OSE
TIME
ST
ALL FOR
CE
CLOSE
EDGE
1
2
3
4
5
6
7
PO
WER
INPUT
S
LOCK
PWR
AU
X
R
LY
C
ONTR
OL
OUTPUT
S
ON
LEARN RMT
LEARN
MAST LIMIT
LEARN
SLV LIMIT
S3
S4
S2
ON
ON
PUSH
SIMULT.
ON
ON
MAX
3
2
4
1
Control Box Settings
Setting Push-to-Open (Open) Gate Limit
(for pull-to-open go to pg. 26)
Press button on opener remote to close gate.
Hold the “LEARN MASTER LIMIT” button for 10 seconds,
or until the alarm sounds to clear. Go back to setting open gate
limit step 1 at the top of this page.
2
3
5
1
15
FUSE
B
AT
T+
B
AT
T-
1 2
3 4
ON
ST
A
TUS
LEA
R
N
RMT
RE
CEIVER
LEARN
MA
ST
LI
MIT
LEARN
S
LV
L
IM
IT
S3
S4
AL
M
S2
OFF
SOF
T S
TAR
T
OFF
W
ARNING
OFF
OPE
N
P
ULL
SL
V
OPEN
D
LY
.
MOD
E1
O
FF
MOD
E2
O
FF
ON
ON
PUS
H
SIMUL
T.
ON
ON
120
MIN
MA
X
GT
O R
CVR.
WHT
BLU
BRN
ORG
RED
BLK
GRN
WHT
BLU
BRN
ORG
RED
BLK
GRN
COM
GRN
BLK
RED
CYCLE
SAFETY
EXIT
SHADOW
OPEN
EDGE
COM
G
TO
TR
ANSF
LOCK
P
WR
AU
X
R
LY
PO
WER
INPUT
S
C
ONTR
OL
INPUT
S
MASTER C
ABLE
SL
A
VE C
ABLE
C
ON
TR
OL INPUT
S
A
UT
O CL
OSE
TIME
ST
ALL FOR
CE
CLOSE
EDGE
18 V
A
C
or
SOL
AR
G
TO
LOCK
AU
X
1
2
3
4
5
6
7
ON
LEARN RMT
LEARN
MAST LIMIT
LEARN
SLV LIMIT
S3
S4
S2
ON
ON
PUSH
SIMULT.
ON
ON
MAX
6
Resetting Open Gate Limit
NOTE: if the gate stops and reverses see “setting obstruction stall
force” page 28.
NOTE: If the unit does not