background image

22

23

Pos. 

No. 

Varebetegnelse 

Description of goods

 

 

Warenbezeichnung 

Désignation des pièces

35.4  80160205  PTFE trådleder blå 1,5x4,0x10m til ø0,8-1,0 tråd 

PTFE wire liner blue 1.5x4.0x10m for ø0.8-1.0 wire

 

 

PTFE Führungsspirale blau 1,5x4,0x10m für ø0,8-1,0 Draht  Guidage de fil PTFE bleu 1,5x4,0x10m pour fil ø0,8-1,0

35.5  80160206  PTFE trådleder rød 2,0x4,0x10m til ø1,2-1,6 tråd 

PTFE wire liner red 2.0x4.0x10m for ø1.2-1.6 wire

 

 

PTFE Führungsspirale rot 2,0x4,0x10m für ø1,2-1,6 Draht 

Guidage de fil PTFE rouge 2,0x4,0x10m pour fil ø1,2-1,6

35.6  80160207  PTFE trådleder gul 2,7x4,5x10m til ø1,6-2,0 tråd 

PTFE wire liner yellow 2.7x4.5x10m for ø1.6-2.0 wire

 

 

PTFE Führungsspirale gelb 2,7x4,5x10m für ø1,6-2,0 Draht  Guidage de fil PTFE jaune 2,7x4,5x10m pour fil ø1,6-2,0

36.1  26310118  Rør til trådleder ø4x121mm 

Pipe for capillary tube ø4x121mm

 

 

Rohr für Kapillarrohr ø4x121mm 

Porte tube capillaire ø4x121mm

36.2  26510155  Kapillarrør ø1,2x128mm, hvid  

Capillary tube ø1.2x128mm white

 

 

Kapillarrohr ø1,2x118mm, weiss 

Tube capillaire ø1,2x128mm, blanc

36.3  26510156  Kapillarrør ø1,5x128mm, blå 

Capillary tube ø1.5x128mm blue

 

 

Kapillarrohr ø1,5x118mm, blau 

Tube capillaire ø1,5x128mm, bleu

36.4  26510157  Kapillarrør ø2,0x128mm, rød 

Capillary tube ø2.0x128mm red

 

 

Kapillarrohr ø2,0x118mm, rot 

Tube capillaire ø2,0x128mm, rouge

36.5  26510158  Kapillarrør ø2,7x128mm, gul 

Capillary tube ø2.7x128mm yellow

 

 

Kapillarrohr ø2,7x118mm, gelb 

Tube capillaire ø2,7x128mm, jaune

  *    

Sliddele monteret som standard  

Fitted as standard equipment

 

 

Montiert als Standard  

Équipements standards

Reservedelsliste - Spare parts list - Ersatzteilliste - Liste des pièces de rechange

Summary of Contents for Push Pull FKS 400

Page 1: ...Brugsvejledning User guide Betriebsanleitung 50115072 Valid from 2021 week 26 Push Pull FKS 400 torch...

Page 2: ...nmark hereby declare that our welding hoses as stated below Type Push Pull FKS 400 torch conforms to directives EC Low Voltage Directive 73 23 EEC Appendix 111 European standards EN IEC60974 7 2019 Is...

Page 3: ...ller andres sikkerhed i fare Ved forkert brug af svejsemaskinen kan du f st d fra en h jfrekvenst nding HF Det er ikke farligt at f st d fra en h jfrekvenst nding p en svejsemaskine Men du skal altid...

Page 4: ...vendig for at undg at stik og kabler del gges Push pull FKS 400 er en svejseslange med integreret frem f ringsenhed til manuel svejsning i bl de svejsetr de og med lange svejseslanger To pr cisionstri...

Page 5: ...en 2 af ZA tilslutningen Spids enden p PA lineren 3 i en 60 graders vinkel F r lineren 3 igennem tr df reren ind i ZA tilslutningen 1 indtil en m rkbar modstand m rkes F r klemnippel 5 O ring 4 og m t...

Page 6: ...skruetr kker Tekniske data Motortype DC str m Elektrode polaritet Som regel positiv Br ndertype Manual Tr dtype Runde tr de p markedet Beskyttelsesgas DIN EN 439 CO2 og blandgas M21 Br nderdata iht E...

Page 7: ...m begge ender og udskift efter behov Udskift kontaktdyse eller tr d Juster efter behov Kontroller hjulet og udskift efter behov Kontroller sporet i trisserne i forhold til valgt tr d V spor til Fe har...

Page 8: ...8...

Page 9: ...e will not jeopardize the safety of you and other persons Improper use of the welding machine may cause shocks from a high frequency HF ignition Getting shocks from a high frequency ignition on a weld...

Page 10: ...MIG non pulse 30 m 60 m a b c Important In order to avoid destruction of plugs and cables good electric contact is required when connecting earth cable and welding hose to the machine The Push Pull F...

Page 11: ...wrench Mount the liner PA Lay down the welding hose straight and unscrew nut 2 from the central connector 1 Sharpen the beginning of the PA liner 3 to an angle of 60 Slide PA liner 3 through the wire...

Page 12: ...rewdriver Technical data Type of Voltage Motor Pull DC direct voltage Elektrode Polarity usually positiv Type of torch use manual Types of wire commercially available round wires Shield Gas DIN EN 439...

Page 13: ...sides and replace if required Replace contact tip or wire Adjust according to manufacturer specifications Inspect wheel and replace if required Verify the groove in the wire drive rolls according to s...

Page 14: ...14...

Page 15: ...r Schwei maschine kann jedoch elektrische Schl ge von einer Hochfrequenz HF Z ndung verursachen Schl ge durch die Hochfrequenz Z ndung einer Schwei maschine sind nicht gef hrlich es empfiehlt sich abe...

Page 16: ...c Wichtig Achten Sie auf festen Sitz der Anschl sse von Massekabel und Schwei schlauch Die Stecker und Kabel k nnen sonst besch digt werden PP FKS 400 ist ein Schutzgas Schwei brenner mit integriertem...

Page 17: ...off Schlauchpaket gestreckt auslegen und am Zentralstecker 1 die berwurfmutter 2 abschrauben Anfang des Liners Kunststoff 3 um rund 60 anspitzen Liner Kunststoff 3 durch den Drahtf rderschlauch bis zu...

Page 18: ...tz Schraubendreher Technische Daten Spannung Motor Pull Gleichspannung DC Polung Elektrode positiv Brennerf hrung manuell Schwei dr hte handels bliche Runddr hte Schutzgas DIN EN 439 CO2 und Mischgas...

Page 19: ...sen und ggf ersetzen Kontaktspitze oder Draht ersetzen Nach Herstellerangaben justieren Das Ritzel kontrollieren und austauschen wenn notwendig Kontrollieren Sie die Spur in den Drahtvorschubrollen un...

Page 20: ...PP FKS 400 curved Smart Torch 10m 1 2 wire drive roll U groove PP FKS 400 gebogen Smart Torch 10m 1 2 Drahtrolle U SpuhrPP FKS 400 courb Smart Torch 10m galet 1 2 U trace 1 80850450 Svanehals 35 krum...

Page 21: ...10x30mm CuCrZr Tube contact 1 2 M8 10x30mm CuCrZr 4 21 80231208 Kontaktdyse 1 4 M8 10x30mm CuCrZr Contact tip 1 4 M8 10x30mm CuCrZr Stromd se 1 4 M8 10x30mm CuCrZr Tube contact 1 4 M8 10x30mm CuCrZr...

Page 22: ...t V Spuhr 1 2mm Fe Kit bobines V trace 1 2mm Fe 30 4 73940134 Trissekit U spor 0 8mm Alu Wire rolls kit U groove 0 8mm Alu Drahtrollen kit U Spuhr 0 8mm Alu Kit bobines U trace 0 8mm Alu 30 5 73940135...

Page 23: ...aht Guidage de fil PTFE jaune 2 7x4 5x10m pour fil 1 6 2 0 36 1 26310118 R r til tr dleder 4x121mm Pipe for capillary tube 4x121mm Rohr f r Kapillarrohr 4x121mm Porte tube capillaire 4x121mm 36 2 2651...

Page 24: ...24...

Page 25: ......

Page 26: ...st ho 451 CZ 415 03 Teplice 3 Czech Republic Tel 420 411 135 600 www migatronic com Hungary MIGATRONIC KERESKEDELMI KFT Fut utca 37 6 emelet H 1082 Budapest Hungary Tel 36 70 630 0604 www migatronic c...

Reviews: