![Migatronic PI 200 AC/DC HP Instruction Manual Download Page 19](http://html1.mh-extra.com/html/migatronic/pi-200-ac-dc-hp/pi-200-ac-dc-hp_instruction-manual_1793455019.webp)
19
Dynamic Oxide Control
(for AC welding).
0 = disabled
1 = enabled (default setting)
Torch Remote Control
Makes it possible to control how the
control unit on the handle is used when torch
adjustment is enabled.
0 = Setting the current reference (factory
default).
1 = Enabling/disabling TIG-A-Tack (the TIG-A-
Tack button is disabled). The control unit is
handled as follows:
Steps 1-3:
TIG-A-Tack is enabled
Steps 4-7:
The trigger is disabled
Steps 8-10: TIG-A-Tack is disabled
2 = Up/Down module
Trigger Trigger
Enabling/Disabling
TIG-A-Tack
* Keep pressed for
constant
increase/reduction
All above settings are not modified via Reset.