9
TECHNICAL DATA
Model
ML 240
ML360
MV 240
MV 400 FKS
MV 500 FKS
Duty cycle
- Co
2
60%
250 A
380 A
300 A
415 A
560 A
- Co
2
100%
225 A
340 A
300 A
415 A
560 A
- Mixgas 60% *
220 A
310 A
270 A
350 A
520 A
- Mixgas 100% *
195 A
270 A
270 A
350 A
520 A
Technique:
Max. open circuit voltage
113 V
113 V
113 V
113 V
113 V
Cooling
air
air
water
water
water
Min. flow rate watercooling 1 bar -
-
1 l/min
1 l/min
1 l/min
Max. pressure (water)
-
-
5 bar
5 bar
5 bar
Max. watertemp.
60°C
60°C
60°C
Gas flow ±5% **
15 l/min
15 l/min
15 l/min
18 l/min
18 l/min
Wirediameter, mm
0,6 – 1,6
0,6 – 1,6
0,6 – 1,8
0,8 – 2,4
0,8 – 2,4
Cable, mm²
25
50
16
16
16
Lenght of cable
3/4m
3/4m
3/4m
3/4m
3/4m
Weight ***
1,2 kg
1,8 kg
1,5 kg
1,6 kg
1,7kg
Total weight kg, 3m
2,1 kg
4,0 kg
3,0 kg
3,1 kg
3,2 kg
Total weight kg, 4m
2,6 kg
4,7 kg
3,6 kg
3,7 kg
3,8 kg
Connection
ZA
ZA
ZA
ZA
ZA
Lenght of swan neck ****
12,5 cm
16,5 cm
11,0 cm
13,5 cm
15,0 cm
Norm:
EN/IEC60974-7
Yes
Yes
Yes
Yes
Yes
* ArCo
2
(82/18)
** Minimum gas flow
for compliance with
*** Weight
**** Lenght of swan neck
max. performance
Dispose of the product according to local standards and regulations.