10
EC DECLARATION OF CONFORMITY
MIGATRONIC A/S
Aggersundvej 33
9690 Fjerritslev
Denmark
hereby declare that our machine as stated below
Type: FOCUS TIG 161 DC
PFC
conforms to directives 2014/35/EU
2014/30/EU
2011/65/EU
European standards:
EN/IEC60974-1
EN/IEC60974-3
EN/IEC60974-10 (Class A)
Issued in Fjerritslev 01.07.2019.
Niels Jørn Jakobsen
CEO
*) The machine enables down to -40% by reducing the max. amperage
1)
S
The machine meets the standards which are demanded of machines working in areas where there is an increased risk of electric shock
2) Equipment marked IP23S is designed for indoor and outdoor applications
Technical data
Power source
FOCUS TIG 161 DC PFC
Mains voltage *) ±10% (50Hz-60Hz), V
1x230
Minimum generator size, kVA
8.3
Fuse, A
16
Mains current effective, A
12.9
Mains current max., A
23.1
Power (100%), kVA
3.0
Power max., kVA
5.1
Power open circuit, W
60
Efficiency
0.8
Power factor
0.99
TIG
MMA
Duty cycle
100%
40°, A/V
110/14.4
100/24.0
Duty cycle
60%
40°, A/V
130/15.2
110/24.4
Duty cycle
max.
40°, A/%/V
160/35/16.4
160/30/26.4
Current range, A
10-160
10-160
Open circuit voltage, V
95
1
Sphere of application
S/CE
2
Protection class (IEC 529)
IP23S
Standards
EN/IEC60974-1.
EN/IEC60974-3.
EN/IEC60974-10
Dimensions (HxWxL), mm
250x180x480
Weight, kg
9.2
Function
Process
FOCUS TIG 161 DC PFC
Arc-power, %
Electrode
40
Hot-start, %
Electrode
40
Anti-freeze
TIG/Electrode
Always on
Stop current, %
TIG
20
Slope-up, s
TIG
0.0-20.0
Slope down, s
TIG
0.0-20.0
Gas pre-flow, s
TIG
0.0-10.0
Gas post-flow, s
TIG
0.0-20.0
Pulse time, s
TIG
0.01-10.0
Pause time, s
TIG
0.01-10.0
Base AMP, %
TIG
10-90
TIG-ignition
TIG
HF/LIFTIG
Triggerfunction, 2-stroke/4-stroke
TIG
2/4
0
10
20
30
40
50
60
70
80
90
100
0
40
80
120
160
I2 [A]
Focus TIG 161 DCHP PFC
TIG Load line
MMA Load line
Static Characteristic
Summary of Contents for FOCUS TIG 161 DC PFC