8.1.3
Cleaning of the vaporizer glass
Carefully read and observe the safety instructions in
section 8.1. before you carry out this maintenance work!
We recommend to empty the vaporizer glass regularly (approx.
once per month, depending on the operating hours) (
see
illustration 8.1.3.A.
) and to clean it with hot water before you
refill it again.
Dispose of the residual vaporizer liquid according to the
instructions given on the label of the container. Read and
observe the instructions given in
section 9.3
.
1. Switch off the gas production at the
on/off
key
I/O
at the
operating panel.
2. Unscrew the fastening ring by turning it to the left (
see
illustration 8.1.3.D
.).
3. Remove the vaporizer glass. Move the complete top part
sideways to facilitate removal of the vaporizer glass.
4. Clean the glass as described above.
5. Remount the vaporizer glass by screwing the fastening ring
back to the right (
see illustration 8.1.3.E
.).
6. Fill the glass with vaporizer liquid as described in
section 8.1.2
.
Illustration 8.1.3. Vaporizer glass (A) with sintered piece (F) and
compensation tank (G) / dryer glass (C) with filter cartridge (B)
WARNING!
How to proceed
A
C
B
D
E
D
E
F
G