Technical Information
71
T1302, T1303, T1322, T1329ci, T1323c,
T1403 and T1405 Clothes Dryers
Table 060-6:
Service Mode (continued from Table 060-5)
TEST STEP
Flashing Rhythm
Of Drying LED
SERVICE
LEVEL
Flashing
Rhythm Of
Buzzer
LED
SERVICE
FUNCTION
Long Short
Function Tested/Machine Response
–
1
Float Switch Test (condenser
models). Buzzer operates when the
float switch is activated.
3
Digital
sensor test
–
2
Door Switch Test - Buzzer operates
when the door is closed.
4
Operating
hours
For
1000s h
For
100s h
Long flashing pulses for thousands,
short flashing pulses for hundreds.
(e.g. 12 x long + 6 x short = 12000 h +
600 h = 12600 h)