Technical Information
63
T1302, T1303, T1322, T1329ci, T1323c,
T1403 and T1405 Clothes Dryers
3 Fault
Repair
3.1
Fault
Summary
1.
Turn on the appliance
2.
Select a program.
3.
Press Start.
4.
Allow the appliance to operate for at least two minutes.
5.
Observe the display for the following:
Table 060-1:
Fault Summary
Fault Signal
Cause
LED
Buzzer
(if turned
on)
Fault
Code
Check(s)
Child Lock LED
flashes
– –
Lock function activated.
Turn off the Child Lock Feature (see 3.2)
Empty out container
LED lights
(condenser dryers
only)
Intermittent
–
Condensate container float switch.
Empty out condenser drawer. Check pump for correct
operation.
Rotary iron LED
flashes (5 Hz)
Intermittent
F2
Heater Bank NTC Temperature Sensor (2R30).
Check the Temperature Sensor and circuit.
Hand iron LED
flashes (5 Hz)
Intermittent
F4
Drum Support housing NTC Temperature Sensor (1R30)
Fault.
Check the Temperature Sensor and circuit.
Anti-crease/Finish
LED lights
Intermittent
–
No load in drum or no-load registered by the Residual
moisture sensor. Ensure laundry is present. Check the
Residual Moisture Sensor circuit.
Anti-crease/Finish
LED lights
Intermittent
F55
Program time limit exceeded. Ensure the Heater Elements are
operating.
Anti-crease/Finish
LED lights
– F41
Programming / Electronic fault. Check wiring and connectors.
Replace the electronic.