Technical Information
T300 Series Clothes Dryer (Condenser)
6.6.2
Fan Operates but the Drum Fails to Turn
Possible Cause
Capacitator for drum motor and fan is defective.
Fault Rectified
As from Machine no. 9414823, the capacitator for the drum motor is
situated on the housing of the cooling fan.
Remedy
If this fault occurs on appliances with a Machine no. lower than that
mentioned above, Conversion Kit, Part no. 2330870, should be used in
accordance with Conversion Instruction 12-7.8.
6.7
Water Container Drawer
6.7.1
Drawer Cannot be Fully Closed
Possible Cause
The container spout snap closure is too strongly sprung and does not
open sufficiently to allow the drawer to close.
Fault Rectified
From Water container, Part no. 1653361.
Remedy
Fit a weaker spring, Part no. 1670291.
6.7.2
Water Container Does Not Locate Correctly When Pushed In
and Opens Again
Possible Cause
Container hook does not click into place on the front panel.
Fault Rectified
Stronger hook on water container from the following Machine nos:
T 368 C 11/8340290
T 369 C 10/8327806
T 377 C 10/8351834
T 378 C 10/8351854
T 382 C 11/8307042
T 388 C 10/8307367
61